23
Technical Product Specification
Getting Started
2.3
Installing the System
It is mandatory that all unused rear slots are filled with blank filler panels and all unused front slots
be filled with air management blades. Empty power supply slots and CMM slots should be covered
with 3U filler panels. These are needed to ensure proper chassis cooling and to maintain
compliance with mandatory U.S. and international electromagnetic regulatory standards.
Ensure the blank filler panels and air management blades include EMI gaskets and are compatible
with CompactPCI* industry standard. See the Intel
®
NetStructure
TM
ZT 5085/88/89/90/91 Chassis
Compatibility Report for a list of compatible blank filler panels and air management blades.
Warning:
Failure to cover open slots could cause overheating of power supplies, boards, or other
components, and could damage the system.
Figure 10. ZT 5085 Example System (Rear)
B2035-01
Rear Panel I/O Boards
(for system master boards)
[Slots 7, 8, 16, and 17]
Exhaust
Grill
AC or DC Power Input Panel
(behind protective cover)
Filler Panels
in all Empty
Slots
Power
Standby
Switch
ESD
Ground
Jack
Содержание NetStructure ZT 5085
Страница 8: ...8 Technical Product Specification ...
Страница 20: ...20 Technical Product Specification Introduction ...
Страница 46: ...46 Technical Product Specification Field Replaceable Units ...
Страница 60: ...60 Technical Product Specification Cooling Subsystem ...
Страница 92: ...92 Technical Product Specification Specifications ...
Страница 94: ...94 Technical Product Specification Power Supplies Hot Swap Circuitry ...
Страница 96: ...96 Technical Product Specification Data Sheet Reference ...
Страница 100: ...100 Technical Product Specification Warranty Information This page intentionally left blank ...
Страница 102: ...102 Technical Product Specification Customer Support This page intentionally left blank ...