Heatsink Clip Load Metrology
R
Thermal/Mechanical Design Guide
71
B.3.1
Time-Zero, Room Temperature Preload Measurement
1.
Pre-assemble mechanical components on the board as needed prior to mounting the
motherboard on an appropriate support fixture that replicates the board attach to a target
chassis.
•
For example: standard ATX board should sit on ATX compliant stand-offs. If the attach
mechanism includes fixtures on the back side of the board, those must be included, as the
goal of the test is to measure the load provided by the actual heatsink mechanism.
2.
Install the test vehicle in the socket
3.
Assemble the heatsink reworked with the load cells to motherboard as shown for the Intel
RCBFH-3 reference heatsink example in Figure 26, and actuate attach mechanism.
4.
Collect continuous load cell data at 1 Hz for the duration of the test. A minimum time to
allow the load cell to settle is generally specified by the load vendors (often in the order of
3 minutes). The time zero reading should be taken at the end of this settling time.
5.
Record the preload measurement (total from all three load cells) at the target time and
average the values over 10 seconds around this target time as well, i.e. in the interval , for
example over [target time – 5 seconds ; target time + 5 seconds].
B.3.2
Preload Degradation under Bake Conditions
This section describes an example of testing for potential clip load degradation under bake
conditions.
1.
Preheat thermal chamber to target temperature (45 ºC or 85 ºC for example)
2.
Repeat time-zero, room temperature preload measurement
3.
Place unit into preheated thermal chamber for specified time
4.
Record continuous load cell data as follows:
•
Sample rate = 0.1 Hz for first 3 hrs
•
Sample rate = 0.01 Hz for the remainder of the bake test
5.
Remove assembly from thermal chamber and set into room temperature conditions
6.
Record continuous load cell data for next 30 minutes at sample rate of 1 Hz.
§
Содержание 640 - Pentium 4 640 3.2GHz 800MHz 2MB Socket 775 CPU
Страница 14: ...Introduction R 14 Thermal Mechanical Design Guide ...
Страница 38: ...Thermal Management Logic and Thermal Monitor Feature R 38 Thermal Mechanical Design Guide ...
Страница 52: ...Intel Thermal Mechanical Reference Design Information R 52 Thermal Mechanical Design Guide ...
Страница 60: ...Acoustic Fan Speed Control R 60 Thermal Mechanical Design Guide ...
Страница 72: ...Heatsink Clip Load Metrology R 72 Thermal Mechanical Design Guide ...
Страница 97: ...Mechanical Drawings R Thermal Mechanical Design Guide 97 Figure 48 Reference Clip Drawings Sheet 1 ...
Страница 98: ...Mechanical Drawings R 98 Thermal Mechanical Design Guide Figure 49 Reference Clip Drawings Sheet 2 ...
Страница 99: ...Mechanical Drawings R Thermal Mechanical Design Guide 99 Figure 50 Reference Fastener Sheet 1 ...
Страница 100: ...Mechanical Drawings R 100 Thermal Mechanical Design Guide Figure 51 Reference Fastener Sheet 2 ...
Страница 101: ...Mechanical Drawings R Thermal Mechanical Design Guide 101 Figure 52 Reference Fastener Sheet 3 ...
Страница 102: ...Mechanical Drawings R 102 Thermal Mechanical Design Guide Figure 53 Reference Fastener Sheet 4 ...
Страница 103: ...Mechanical Drawings R Thermal Mechanical Design Guide 103 Figure 54 Clip Heatsink Assembly ...
Страница 104: ...Mechanical Drawings R 104 Thermal Mechanical Design Guide Figure 55 Intel R RCBFH 3 Reference Solution Assembly ...