TwinLock B600 CashProtect
Operation
Manual V.1.04A
29
4.6.2
Selecting the Master / CIT master
Lock - and CIT master select
‘
Master
’
/
‘
CIT master
’ before
entering code:
1.
As master / CIT master, follow the steps of an instruction until code input is
required.
Before code input is required from the master or the CIT master,
Code entry | User: Master
is displayed.
2.
Confirm
Master
with
Enter
or with menu key
>
select
CIT master
and press key
Enter
.
CIT master
or
Master
,
Code entry
,
0123456789
, as it may be, and
Code:
are displayed.
3.
If required, continue following the instruction.
You have successfully selected master / CIT master.
.
4.7
User Authorisation
Before entering code, users enter their user
–
or personnel number (
“
staffnb
” on the
display of the operating unit). The following does not apply for the operation with
OTC flexible, for which personnel numbers are required. See the instructions above.
With the exception of the operation with OTC flexible, the system administrator
defines the authorisation of users via CashProtectPro by ticking / marking boxes for
persons in a user matrix; descriptions of these boxes see below. The authorisation
within a lock system can be changed via optional PC software.
In order to establish a certain order of authorisation in system TwinLock CashProtect,
the system administrator imports a configuration generated with PC software into
system TwinLock CashProtect.
In order to grant a user the right to open a lock, the lock master (holder of the master
code of the lock) also has to register one or more of the following items for the user
at the lock:
•
PIN code or PIN code and, for user identification, RFID card
If box
Release
is not ticked / marked for a user in the user matrix, this user will not
have any rights and no function will be available for her or him.
Authorisation for opening locks via entering PIN code:
The system manager marks boxes
PIN code
,
Release
,
Open locks
for the user.
Authorisation for user identification via RFID:
The system manager ticks / marks the boxes
Card
,
Release
and
Open locks
.
Additionally, the value „
DESFire
“ has to be set for parameter „C
ode
card“ on tab
„
Code s
ettings“ via
PC software.