TwinLock B600 CashProtect
Operation
Manual V.1.04A
50
4.13.11
Alarm Devices: XT Extension / TwinAlarm
Caution
Risk that
„No release“ is displayed upon an
attempt at opening the lock after the activation
of the extension unit.
After activating the extension unit, both inputs are
active.
Deactivate
input
„Release“
via
optional
PC software or TwinNet, if possible.
Settings
Alarm device is part of the system.
1.
Unlock the system by opening lock 1 or by opening all locks.
2.
With key > and with key
Enter
select
Settings
.
Settings | Manager
is on display.
3.
Confirm
Manager
with
Enter
.
System manager | Code entry
, and
Code:
are on display.
4.
Enter the system code.
Manager | Change code
are on display.
5.
With
>
and
Enter
select
Alarm devices
.
Alarm devices | TwinXT
is on display.
6.
With
>
and
Enter
select
TwinXT
, if required.
TwinXT active | * = YES * = NO
is on display.
7.
With
>
and
Enter
select
* = YES
or
* = NO
, as requested.
With the alarm device deactivated,
TwinXT active | Deleted
is on display.
With the alarm device activated,
A:1<:1R:1F:0C:0
is on display.
A = analysis of inputs bolt work/release (0=active open/1=active closed)
B = bolt work (0/1)
R = Release (0/1), input
F = detour bolt work at keypad [available only with A=1] (0/1)
C = automatic closing with DS [door switch] (0/1)
< = cursor position
0 = not active; 1 = active
Where C is concerned, 0 = NO, normal open; 1 = NC, normal closed.
8.
With
1
or
0
and
Enter
select the settings required.
TwinXT active | Saved
is on display.
You have successfully configured an alarm device and / or switched it on / off.