background image

a

Property Damage: 

All tubes must be cut 

squarely with no burrs. 

  

Attach supplied quick connect elbow 

to end of supplied 

white 

1/4" tube.

  

Attach quick connect elbow to water 

Inlet

 on front of chilled water tank.

  

Measure distance from water inlet 

on chilled water tank to water 

supply valve. Carefully trim 

white 

1/4" tube, allowing 

ample slack in tubing.

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

HOW TO USE THIS INSTRUCTION MANUAL

These instructions are separated into main sections, indicated by numbers, and 

subsections, indicated by capital letters. The manual is setup this way to allow you to 

take a break at any point after completing a section or subsection without affecting the 

installation process. 

What you’ll see in the 

instruction manual:

1

2

3

Equipment You May Need:

 

IMPORTANT: After unpacking chilled water tank, place the unit upright for 1 hour before 

connecting power.

  

For best results, the cold water faucet should be installed prior to installing the chilled water tank.

  

The C1100 Cold Only Faucet is designed for use with the CWT-00 Chilled Water Tank as a system (with 

optional InSinkErator Filtration System).

  

For your satisfaction and safety, read all instructions, cautions and warnings before installing or using 

this chilled water tank.
This particular unit is not intended for commercial use.

  

Make sure that all electrical wiring and connections conform to local codes.

  

A standard 115-volt grounded electrical outlet is required under the sink for the chilled water tank’s 

electrical power.

  

It is recommended that a separate circuit providing power only to the chilled water tank be used.

  

The wall outlet powering the chilled water tank must be fused and should not be controlled by the same wall 

switch used by the food waste disposer.

  

It is recommended that a dedicated control valve be installed on the cold water line supplying water to this 

system. Make sure all water supply control valves do 

not

 have a backflow preventer in them.

  If you suspect elevated levels of chlorine in your water, it is recommended to use our water filtration system. 

  

The water pressure to the chilled water tank should be between a minimum of 30 psi (207kPa) and 

a maximum of 100 psi (689kPa). 

  

The chilled water tank may cause an increase in temperature in your cabinet when running.

  

The chilled water tank has a refrigeration compressor, which may generate noise while running.

  

The chilled water tank should only be installed in an upright position.

  

The chilled water tank is intended only for chilling water. 

WHAT YOU SHOULD KNOW BEFORE YOU BEGIN

If you will be installing a dedicated cold only water faucet and intend to use the sprayer hole in your sink for that 

faucet, you may need a basin wrench and a 1/8" plug or a 1/4" hose line cap (

not supplied

).

If you need to cut a mounting hole in your stainless steel sink, you may need a 1-1⁄4" – 1-1⁄2" hole saw made 

for cutting stainless steel or a hole punch. Consult a professional if you are drilling into a surface other than 

stainless steel.

Equipment Required:

 (sold separately)

Cold water faucet

n  

T-fitting

n  

Dedicated control valve

Adjustable wrench

n  

Utility knife 

Tape measure / ruler

WHAT YOU NEED TO GET STARTED

Provides a step-by-step narrative describing the installation step, with check boxes that 

can be marked as you progress through the installation.

Contains simple illustrations that provide visual instruction to support the narrative.

CAUTIONS and WARNINGS that will require your attention during the step.

1

2

3

A potentially hazardous situation, which, if not avoided, could result in death or serious injury.

Caution, used with the safety alert symbol, indicates a hazardous situation which, if not 

avoided, could result in minor or moderate injury.

Caution, without the safety alert symbol, is used to address practices not related to  

personal injury.

PACKAGE COMPONENTS

Chilled Water Tank

Quick Connect Elbows (3)

White Tubing - 4'

Blue Tubing - 4'

Cold Only Faucet

Rubber O-Ring

Hex Nut

Semi-circular

Mounting Plate

1/4" Brass Insert

Hex Tool

CWT-00

C1100

Y-Quick Connector

Plug (1)

Congratulations on your purchase of this quality InSinkErator

®

 water product. In addition 

to complete operating and care instructions, in this Owner’s Manual you will find instructions  

for installing both:

•  CWT-00 Chilled Water Tank with an existing hot/cool water dispenser – 

See pages 4-6

•  CWT-00 Chilled Water Tank with a C1100 Cold Only Faucet – 

See pages 7-9

3

2

Hole saw / hole punch    Basin wrench    1/4" Tube insert, ferrule and nut

Содержание Chilled Water Tank & Cold Only Faucet CWT-00

Страница 1: ...utilisation The Emerson logo is a trademark and service mark of Emerson Electric Co Printed in U S A 2011 InSinkErator InSinkErator is a division of Emerson Electric Co All Rights Reserved El logotipo...

Страница 2: ...ank should be between a minimum of 30 psi 207kPa and a maximum of 100 psi 689kPa The chilled water tank may cause an increase in temperature in your cabinet when running The chilled water tank has a r...

Страница 3: ...il it stops Insert 1 4 white tube from tank inlet into the 3 8 to 1 4 quick connect fitting Identify copper HOT water tube which is marked with white tape Install that tube into the 3 8 to 1 4 quick c...

Страница 4: ...flows from the spout Allow water to run for at least 60 seconds after water begins to flow from faucet Depress the hot water handle until water flows smoothly 4 FILL TANK CONNECT POWER ass Nut Ferrule...

Страница 5: ...Ferrule Plastic tube 1 4 Inlet Outlet White Tape For filtration installation instructions see installation guide packed with the system Install a T fitting not included onto the cold water supply lin...

Страница 6: ...during the normal course of use including without limitation cosmetic rust scratches dents or comparable and reasonably expected losses or damages Losses or damages caused by the Dornbracht Water Disp...

Страница 7: ...aucet or if there is an objectionable taste or odor to the water When the inlet and outlet ports have been closed and the filter s internal pressure has been relieved water about 2 oz will discharge f...

Страница 8: ...1100 est dise ado para ser usado con el dep sito de agua fr a como un sistema con el Sistema de Filtraci n InSinkErator opcional Para su satisfacci n y seguridad lea todas las instrucciones precaucion...

Страница 9: ...3 Tubo blanco 4 121 9 cm Tubo azul 4 121 9 cm Grifo de agua fr a CWT 00 C1100 Conector r pido con forma de Y Tap n 1 Anillo O de caucho Tuerca hexagonal Placa de montaje semicircular Suplemento de bro...

Страница 10: ...8 1 cm y 1 4 0 6 cm Identifique el tubo de cobre de agua CALIENTE el cual est marcado con cinta blanca Instale dicho tubo en el empalme de conexi n r pida de entre 3 8 1 cm y 1 4 0 6 cm Tuerca de bron...

Страница 11: ...da Por debajo del fregadero coloque la placa de montaje semicircular en el montante roscado Coloque la tuerca hexagonal en el montante roscado Aseg rese de que el grifo est en el ngulo deseado Introdu...

Страница 12: ...ue no haya fugas Conecte el tanque enfriador de agua Antes de beber agua del tanque enfriador d jela correr durante al menos 5 minutos para limpiar las tuber as Espere 60 minutos para que el agua alca...

Страница 13: ...cto InSinkErator de reemplazo El Fabricante o su representante de servicio autorizado bajo su exclusivo criterio determinar n si es necesaria la reparaci n o el reemplazo del producto Recibir todos lo...

Страница 14: ...de la v lvula del grifo lo que ocasiona una leve p rdida de agua Desatornille el extremo del surtidor y limpie los residuos Accione la palanca del grifo de 7 a 10 veces para limpiar el grifo y las tub...

Страница 15: ...entre un minimum de 30 psi 207 kPa et un maximum de 100 psi 689 kPa Lors de son fonctionnement le r servoir d eau r frig r e peut provoquer une augmentation de la temp rature dans votre meuble Le r se...

Страница 16: ...r e du r servoir dans le raccord rapide 3 8 po 1 4 po 1 cm 0 6 cm Identifiez le tuyau en cuivre d eau chaude marqu avec du ruban adh sif blanc Ins rez ce tuyau dans le raccord rapide 3 8 po 1 4 po 1 c...

Страница 17: ...usqu ce que l eau s coule du bec Laissez couler l eau pendant au moins 60 secondes apr s qu elle commence s couler du robinet fontaine Maintenez la poign e d eau chaude en position ouverte jusqu ce qu...

Страница 18: ...tuyau blanc Fixez l autre extr mit du tuyau blanc 1 4 po 0 6 cm fourni dans le raccord compression 1 4 po 0 6 cm et serrez l ensemble Sans syst me de filtration crou en laiton Bague Insert en laiton c...

Страница 19: ...ompris sans en exclure d autres la rouille cosm tique les gratignures les bosselures ou les pertes ou dommages similaires et raisonnablement pr vus Les pertes ou les dommages caus s par le Distributeu...

Страница 20: ...eau du robinet fontaine ou si l eau a un go t ou une odeur d sagr able Lorsque l entr e et la sortie ont t ferm es et que l int rieur du filtre n est plus sous pression l eau environ 2 oz soit 6 cl so...

Отзывы: