background image

b

b

a

a

Property Damage: 

Do not pinch or break copper 

tubing. Do not distort the last 1" of tubing.

2

An assistant may be needed to hold 

the faucet in place 

while securing the base.

Follow these steps for installing chilled water tank with a cold only faucet.

    

Feed tube down through sink hole 

until the base is at rest.

    

From under the sink, place the 

semi-circular mounting plate onto  

the threaded stud. 

    

Place hex nut onto the threaded stud. 

Ensure faucet is at desired angle. 

    

Insert screwdriver into hole on side of 

hex tool (creating a “T”), and use tool 

to tighten nut and secure faucet.

  

Unpack faucet components. 

  

On a firm, flat surface, carefully 

straighten the copper tubing.

       

Ensure that the black O-ring is 

properly seated in the base of the 

faucet (the groove on the underside 

of the faucet base).

Property Damage: 

Do not pinch or break tubing. 

Do not distort the last 1" of tubing.

Pull on connection to ensure fully engaged.

  

Attach supplied quick connect elbow 

to end of supplied 

blue 

1/4" tube.

  

Attach quick connect elbow with 

blue tube to water 

Outlet

 on front of 

chilled water tank.

  

Measure distance from chilled water 

tank outlet to water supply line on 

faucet. Carefully trim blue tube to 

correct length.

  

Using quick connect elbow, connect 

blue tube to faucet water supply.

Property Damage: 

All tubes must be cut 

squarely with no burrs. 

3

  

Attach supplied quick connect elbow 

to end of supplied 

white 

1/4" tube.

  

Attach quick connect elbow to water 

Inlet

 on front of chilled water tank.

  

Measure distance from water inlet 

on chilled water tank to water 

supply valve. Carefully trim 

white 

1/4" tube, allowing ample slack 

in tubing.

White Tape

Follow these steps for installing chilled water tank with a cold only faucet.

Property Damage:

 Join remaining tube to

cold water supply only. Water supply valves

must 

not

 prevent backwards flow.

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

  

For filtration installation instructions, 

see installation guide packed with the 

system.

 

   Install a T-fitting 

(not included) 

onto the cold water supply line.

 

   Install dedicated water control 

valve with 3/8" compression fitting 

(not included).

 

   Install brass nut, ferrule and tube 

insert at the end of the 

white

3/8" 

tube from filter. 

 

   Insert the 

white

 3/8" tube into the 

3/8" compression fitting and tighten.

With optional InSinkErator filtration system:

Property Damage:

 Before plugging in 

chilled water tank, check for leaks in all  

water supply connections. 

    

Turn on the cold water supply. 

  

Depress the faucet handle and hold it 

until water flows from the spout.

  

Allow water to run for at least 60 

seconds after water begins to flow 

from faucet.

5

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

9

8

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

b

    

Check all connections to ensure they 

are tight and that there are no leaks.

 

   Plug in chilled water tank.

 

   Prior to drinking water from the 

chilled water tank, run the water for  

at least 5 minutes to flush lines.

Allow up to 60 minutes for  

water to reach target temperature.

Electric Shock Hazard:

 A standard grounded

outlet is required under the sink. Do not use an 

extension cord set with the chilled water tank. 

Brass Nut

Ferrule

Brass Insert

Wing Nut

Plug

Fiber 

Washer

Brass Nut

Ferrule

Wing Nut

Fiber 

Washer

1

2

3

Plastic

tube

Property Damage:

 Join remaining tube to

cold water supply only. Water supply valves 

must 

not

 prevent backward flow.

4

 

   Install a T-fitting 

(not included) 

onto the cold water supply line.

 

   Install dedicated water control valve with 

1/4" compression fitting 

(not included)

.

 

   Place 1/4" brass insert 

(included) 

into end of white tube. 

 

   Attach remaining end of the supplied 

white 

1/4" tube into the 1/4" 

compression fitting and tighten.

With no filtration system:

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

Brass Nut

Ferrule

Brass Insert

Brass Nut

Ferrule

Plastic

tube

1

4

Inlet

Outlet

White Tape

a

a

a

  INSTALLING THE COLD ONLY FAUCET

  INSTALLING THE WATER TANK

  FILL TANK & CONNECT POWER

  WATER CONNECTION 

Содержание Chilled Water Tank & Cold Only Faucet CWT-00

Страница 1: ...utilisation The Emerson logo is a trademark and service mark of Emerson Electric Co Printed in U S A 2011 InSinkErator InSinkErator is a division of Emerson Electric Co All Rights Reserved El logotipo...

Страница 2: ...ank should be between a minimum of 30 psi 207kPa and a maximum of 100 psi 689kPa The chilled water tank may cause an increase in temperature in your cabinet when running The chilled water tank has a r...

Страница 3: ...il it stops Insert 1 4 white tube from tank inlet into the 3 8 to 1 4 quick connect fitting Identify copper HOT water tube which is marked with white tape Install that tube into the 3 8 to 1 4 quick c...

Страница 4: ...flows from the spout Allow water to run for at least 60 seconds after water begins to flow from faucet Depress the hot water handle until water flows smoothly 4 FILL TANK CONNECT POWER ass Nut Ferrule...

Страница 5: ...Ferrule Plastic tube 1 4 Inlet Outlet White Tape For filtration installation instructions see installation guide packed with the system Install a T fitting not included onto the cold water supply lin...

Страница 6: ...during the normal course of use including without limitation cosmetic rust scratches dents or comparable and reasonably expected losses or damages Losses or damages caused by the Dornbracht Water Disp...

Страница 7: ...aucet or if there is an objectionable taste or odor to the water When the inlet and outlet ports have been closed and the filter s internal pressure has been relieved water about 2 oz will discharge f...

Страница 8: ...1100 est dise ado para ser usado con el dep sito de agua fr a como un sistema con el Sistema de Filtraci n InSinkErator opcional Para su satisfacci n y seguridad lea todas las instrucciones precaucion...

Страница 9: ...3 Tubo blanco 4 121 9 cm Tubo azul 4 121 9 cm Grifo de agua fr a CWT 00 C1100 Conector r pido con forma de Y Tap n 1 Anillo O de caucho Tuerca hexagonal Placa de montaje semicircular Suplemento de bro...

Страница 10: ...8 1 cm y 1 4 0 6 cm Identifique el tubo de cobre de agua CALIENTE el cual est marcado con cinta blanca Instale dicho tubo en el empalme de conexi n r pida de entre 3 8 1 cm y 1 4 0 6 cm Tuerca de bron...

Страница 11: ...da Por debajo del fregadero coloque la placa de montaje semicircular en el montante roscado Coloque la tuerca hexagonal en el montante roscado Aseg rese de que el grifo est en el ngulo deseado Introdu...

Страница 12: ...ue no haya fugas Conecte el tanque enfriador de agua Antes de beber agua del tanque enfriador d jela correr durante al menos 5 minutos para limpiar las tuber as Espere 60 minutos para que el agua alca...

Страница 13: ...cto InSinkErator de reemplazo El Fabricante o su representante de servicio autorizado bajo su exclusivo criterio determinar n si es necesaria la reparaci n o el reemplazo del producto Recibir todos lo...

Страница 14: ...de la v lvula del grifo lo que ocasiona una leve p rdida de agua Desatornille el extremo del surtidor y limpie los residuos Accione la palanca del grifo de 7 a 10 veces para limpiar el grifo y las tub...

Страница 15: ...entre un minimum de 30 psi 207 kPa et un maximum de 100 psi 689 kPa Lors de son fonctionnement le r servoir d eau r frig r e peut provoquer une augmentation de la temp rature dans votre meuble Le r se...

Страница 16: ...r e du r servoir dans le raccord rapide 3 8 po 1 4 po 1 cm 0 6 cm Identifiez le tuyau en cuivre d eau chaude marqu avec du ruban adh sif blanc Ins rez ce tuyau dans le raccord rapide 3 8 po 1 4 po 1 c...

Страница 17: ...usqu ce que l eau s coule du bec Laissez couler l eau pendant au moins 60 secondes apr s qu elle commence s couler du robinet fontaine Maintenez la poign e d eau chaude en position ouverte jusqu ce qu...

Страница 18: ...tuyau blanc Fixez l autre extr mit du tuyau blanc 1 4 po 0 6 cm fourni dans le raccord compression 1 4 po 0 6 cm et serrez l ensemble Sans syst me de filtration crou en laiton Bague Insert en laiton c...

Страница 19: ...ompris sans en exclure d autres la rouille cosm tique les gratignures les bosselures ou les pertes ou dommages similaires et raisonnablement pr vus Les pertes ou les dommages caus s par le Distributeu...

Страница 20: ...eau du robinet fontaine ou si l eau a un go t ou une odeur d sagr able Lorsque l entr e et la sortie ont t ferm es et que l int rieur du filtre n est plus sous pression l eau environ 2 oz soit 6 cl so...

Отзывы: