EonStor / EonStor DS S12/S16/S24 Series
83
2U Redundant and 3U RAID Systems PSU & Cooling Module
The 2U-Rxxx and 3U RAID systems come with two redundant, hot-swappable PSUs.
Each PSU has a power socket
(1)
, power switch
(2)
, PSU status LED
(3)
, cooling
module
(4)
, cooling module status LEDs
(5)
, retention screw
(6)
and an extraction
handle
(7)
.
The cooling modules can operate at three rotation speed settings. Under normal
operating conditions, the cooling fans run at the low speed. Under the following
conditions, cooling fans raise their rotation speed to increase the airflow:
Component failure: if a cooling module, PSU, or a temperature sensor
fails.
Elevated temperature: if the temperature breaches the upper threshold
set for any of the interior temperature sensors.
During the system initialization stage, the cooling fans operate at high
speed and return to low speed once the initialization process has
completed and no erroneous condition detected.
NOTE
There are two upper temperature thresholds: one for event notification and the other
for triggering higher fan rotation speed. The preset value for event notification can be
changed using the firmware-embedded configuration utility, while the fan speed
trigger cannot be changed. Refer to the Firmware Operation Manual for details.
44
Содержание EonStor DS S12S-J2000-G
Страница 204: ...IFT 9273CSlide32 36 0100 Slide Rail Kit 10 10 Screws on the forearm securing the enclosure onto the rack 204...
Страница 207: ...IFT 9279CSlider36 Slide Rail Kit R 05 05 07 07 07 07 Attach filler plates to the enclosure 207...
Страница 214: ...IFT 9373CSlider36 Slide Rail Kit 03 03 Securing the enclosure with screws in the front and rear forearm area 214...