BBU Fault Conditions and Precautions
If a BBU leaks, gives off a bad odor, generates heat, becomes discolored or
deformed, or in any way appears abnormal during use, recharging or storage,
immediately remove it from the system and stop using it. Here are some of the
conditions that might trigger BBU fault.
The temperature sensor on the system’s charger circuit reports a
he charger
er is
odule or reset the system.
Follow these precautions when you install the BBU.
e replacement BBU supplied by your distributor. Use of battery
se of used BBUs at authorized battery disposal sites only.
t
temperature reading exceeding the pre-set threshold. T
circuits will enter a low-power and self-protection state.
A BBU module has been charged for over twelve hours. A tim
embedded with the charger. When this occurs, the charger will enter a
timer fault state. Charging will resume automatically after you
remove/re-install the BBU m
Use th
cells provided otherwise will void your warranty.
Dispo
Do not place a BBU near a heat source.
Do not immerse the BBU in water or expose it to liquids.
Do not disassemble or modify the BBU.
Do not pierce the BBU with a sharp object, strike it with a hammer, exer
pressure on it, or throw it.