EonStor / EonStor DS S12/S16/S24 Series
99
Controller Type
There are two types of controllers. Type I controllers allow users to install and
maintain the FBM and BBU while type II only allow users to maintain the BBU. If the
controller of your RAID system has a protrusion at the back of the enclosure as
shown in the illustration below, please see
instructions.
100
Installing the BBU (Type I)
Install the BBU
(1)
by orienting its protruding edge on one end into the insertion slot
(2)
, and lowering it into the canister. The orientation is shown below.
Carefully orient the BBU so that the golden finger connector
(3)
is properly aligned
with that on the charger board
(4)
. There are guide pins on BBU to help properly
align the connectors. Once the connectors are mated, fasten the captive screw
(5)
on BBU to secure the installation.
1
1
2
3
4
5
64