EonStor / EonStor DS S12/S16/S24 Series
configuration
using this configuration. For remote replication
setup, please refer to “
SAN with Port Trunk (Remote Replication Enabled)
”.
4 logical drives (each has 4 member drives; for better
performance, you can include drives from JBOD)
LD0 mapped to CH0 AID and CH0 BID; LD assigned to
controller A
LD1 mapped to CH1 AID and CH1 BID; LD assigned to
controller A
LD2 mapped to CH2 AID and CH2 BID; LD assigned to
controller B
LD3 mapped to CH3 AID and CH3 BID; LD assigned to
controller B
*
LD assignment
NOTE
In the event of single controller failure, a logical drive is accessed through the
host IDs managed by the alternate RAID controller. Host IDs and port IPs do
not fail-over to the surviving controller. Therefore, the EonPath multi-pathing
driver is necessary for path redundancy and controller failover.
94
Содержание EonStor DS S12S-J2000-G
Страница 204: ...IFT 9273CSlide32 36 0100 Slide Rail Kit 10 10 Screws on the forearm securing the enclosure onto the rack 204...
Страница 207: ...IFT 9279CSlider36 Slide Rail Kit R 05 05 07 07 07 07 Attach filler plates to the enclosure 207...
Страница 214: ...IFT 9373CSlider36 Slide Rail Kit 03 03 Securing the enclosure with screws in the front and rear forearm area 214...