![Infineon Technologies XC2200 Скачать руководство пользователя страница 503](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439503.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-243
V2.1, 2008-08
SCU, V1.13
6.14.2
Register Protection Registers
Register SLC
This register is the interface for the protection commands.
SLC
Security Level Command RegisterESFR (F0C0
H
/60
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
COMMAND
rw
Field
Bits
Type
Description
COMMAND
[15:0]
rw
Security Level Control Command
The commands to control the security level must be
written to this register (see table)