XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-99
V2.1, 2008-08
SCU, V1.13
Lower Power Reference (LPR)
The LPR of an EVR is used for following purposes:
•
Operation in a power-save mode other than Active Mode
•
Special power saving in the Active Mode
The LPR can be enabled / disabled via the bit EVRxSETyyV.LPRDIS. If a setting use the
LPR or not is defined via the bit field EVRxSETyyV.VRSEL. Please note that even if bit
EVRxSETyyV.LPRDIS and the bit field EVRxSETyyV.VRVAL are writable this should
not be done, the reset value of the setting registers is already defined in the way the
different setting work.
As the core voltage depends on the LPR the LPR can be adjusted via bit field
EVRxCON0.LPRLEV for application specific fine tuning.
High Precision Bandgap (HP)
The HP bandgap of the system is used for following purposes:
•
Provide a very stable reference for the two EVRs
•
Provide an accurate reference for the flash memory. For more information see the
flash memory description.
Only one HP bandgap is implemented which is used by both EVRs. The HP bandgap
can be enabled / disabled via the bit
.HPEN.