![Infineon Technologies XC2200 Скачать руководство пользователя страница 326](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439326.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-66
V2.1, 2008-08
SCU, V1.13
RSTCNTCON
Reset Counter Control RegisterESFR (F1B2
H
/D9
H
)
Reset Value: 0A0A
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RELD
RELA
rw
rw
Field
Bits
Type
Description
RELA
[7:0]
rw
Application Reset Counter Reload Value
This bit field defines the reload value of RSTCNTA.
This value is always used when counter RSTCNTA is
started.
This counter value is used for Internal Application,
and Application Resets.
In case of an ESRx reset the counter value must be
not less than the reset value.
RELD
[15:8]
rw
Debug Reset Counter Reload Value
This bit field defines the reload value of RSTCNTD.
This value is always used when counter RSTCNTD
is started.
This counter value is used for the Debug Reset.
In case of an ESRx reset the counter value must be
not less than the reset value.