XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-222
V2.1, 2008-08
SCU, V1.13
ESR2T
3
rh
ESR2 Trap Request Flag
TRAPSTAT.ESR2T is set when bit DMPMIT.ESR0T is
set and TRAPDIS.ESR2T = 0.
0
B
No ESR2 trap trigger has occured since this bit
was cleared the last time
1
B
An ESR2 trap trigger has occured since this bit
was cleared the last time
OSCWDTT
4
rh
OSCWDT Trap Request Flag
TRAPSTAT.OSCWDTT is set when an OSCWDT
emergency event occurs and
TRAPDIS.OSCWDTT = 0.
0
B
No OSCWDT trap trigger has occured since this
bit was cleared the last time
1
B
An OSCWDT trap trigger has occured since this
bit was cleared the last time
RAT
5
rh
Register Access Trap Request Flag
TRAPSTAT.RAT is set when bit DMPMIT.RAT is set
and TRAPDIS.RAT = 0.
0
B
No RA trap trigger has occured since this bit was
cleared the last time
1
B
A RA trap trigger has occured since this bit was
cleared the last time
PET
6
rh
Parity Error Trap Request Flag
TRAPSTAT.PET is set when a memory parity error
occurs and TRAPDIS.PET = 0.
0
B
No PE trap trigger has occured since this bit was
cleared the last time
1
B
A PE trap trigger has occured since this bit was
cleared the last time
VCOLCKT
7
rh
VCOLCK Trap Request Flag
TRAPSTAT.VCOLCKT is set when a VCOLCK
emergency event occurs and
TRAPDIS.VCOLCKT = 0.
0
B
No VCOLCK trap trigger has occured since this
bit was cleared the last time
1
B
A VCOLCK trap trigger has occured since this
bit was cleared the last time
0
[15:8]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description