![Infineon Technologies XC2200 Скачать руководство пользователя страница 432](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439432.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-172
V2.1, 2008-08
SCU, V1.13
6.8.6
Output Gating Unit (OGUy)
Each OGUy (y = 0-3) unit combines the available trigger events and status flags from
the Input Channels and distributes the results to the system.
illustrates the
logic blocks within an OGUy unit. All functions of an OGUy unit are controlled by its
associated EXOCONy register, e.g.
for OGU0. The function of an OGUy unit
can be split into two parts:
•
Trigger combination
(see
):
All trigger signals TRxy from the Input Channels that are enabled and directed to
OGUy, a selected peripheral-related trigger event, and a pattern change event (if
enabled) are logically OR-combined.
•
Pattern detection
(see
):
The status flags EXICONx.FL of the Input Channels can be enabled to take part in
the pattern detection. A pattern match is detected while all enabled status flags are
set.
Figure 6-28 Output Gating Unit for Output Channel y
ERU_OGU.vsd
Output Gating
Unit y (OGUy)
ERU_OGUy1
EXICON1.FL
TR0y
TR1y
TR2y
TR3y
ERU_PDOUTy
Detect
Pattern
EXOCONy.
IPEN1
EXICON2.FL
EXOCONy.
IPEN2
EXICON3.FL
EXOCONy.
IPEN3
EXICON0.FL
EXOCONy.
IPEN0
EXOCONy.
PDR
EXOCONy.
GEEN
Combine
OGU
Triggers
(OR)
Select
Periph.
Triggers
ERU_OGUy2
ERU_OGUy3
EXOCONy.
ISS
Select
Gating
Scheme
EXOCONy.
GP
ERU_GOUTy
ERU_IOUTy
ERU_TOUTy
Peripheral
Triggers
Triggers
from Input
Channels
Status Flags
Interrupt
Gating
(AND)