![Infineon Technologies XC2200 Скачать руководство пользователя страница 379](http://html1.mh-extra.com/html/infineon-technologies/xc2200/xc2200_user-manual_2055439379.webp)
XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-119
V2.1, 2008-08
SCU, V1.13
STEP0
Step 0 Register
SFR (FEF2
H
/79
H
)
Reset Value: C063
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RES
PVC
1
OFF
PVC
M
OFF
SYS
DIV
TRGSEL
CLK
EN1
CLK
ENM
V1
VM
rwh rwh rwh rwh
rwh
rwh rwh
rwh
rwh
Field
Bits
Type
Description
VM
[2:0]
rwh
DMP_M Voltage Configuration
This bit defines the DMP_M core supply voltage that
is requested from EVR_M.
000
B
Full Voltage with HP bandgap selected
001
B
Reduced Voltage with LPR selected
010
B
Reserved, do not use this combination
011
B
Full Voltage with LPR selected
100
B
Off is configured
101
B
Off is configured
110
B
Off is configured
111
B
Off is configured