XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-221
V2.1, 2008-08
SCU, V1.13
6.12.3
SCU Trap Control Registers
6.12.3.1 Register TRAPSTAT
This register contains the status flags for all trap request trigger sources of the SCU.
For setting and clearing of these status bits by software see registers TRAPSET and
TRAPCLR, respectively.
TRAPSTAT
Trap Status Register
SFR (FF02
H
/81
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
VCO
LCK
T
PE
T
RA
T
OSC
WDT
T
ESR
2
T
ESR
1
T
ESR
0
T
FA
T
r
rh
rh
rh
rh
rh
rh
rh
rh
Field
Bits
Type Description
FAT
0
rh
Flash Access Trap Request Flag
TRAPSTAT.FAT is set when a flash access violation
occurs and TRAPDIS.FAT = 0.
0
B
No FA trap trigger has occured since this bit was
cleared the last time
1
B
A FA trap trigger has occured since this bit was
cleared the last time
ESR0T
1
rh
ESR0 Trap Request Flag
TRAPSTAT.ESR0T is set when bit DMPMIT.ESR0T is
set and TRAPDIS.ESR0T = 0.
0
B
No ESR0 trap trigger has occured since this bit
was cleared the last time
1
B
An ESR0 trap trigger has occured since this bit
was cleared the last time
ESR1T
2
rh
ESR1 Trap Request Flag
TRAPSTAT.ESR1T is set when bit DMPMIT.ESR1T is
set and TRAPDIS.ESR1T = 0.
0
B
No ESR1 trap trigger has occured since this bit
was cleared the last time
1
B
An ESR1 trap trigger has occured since this bit
was cleared the last time