XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-32
V2.1, 2008-08
SCU, V1.13
PLLCON0
PLL Configuration 0 Register ESFR (F1B8
H
/DC
H
)
Reset Value: 1302
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
N
ACK
0
NDIV
0
REG
EN
SET
REG
EN
CLR
VCOSEL
VCO
PWD
VCO
BY
rw
r
rw
r
w
w
rw
rw
rw
Field
Bits
Type
Description
VCOBY
0
rw
VCO Bypass
0
B
Select divider K2 for PLL clock
(Normal / Unlocked Mode)
1
B
Select divider K1 for PLL clock
(Prescaler Mode, i.e. VCO is bypassed)
Bit PLLSTAT.VCOBYST shows the actually selected
divider.
Note: Coding of VCOBY and PLLSTAT.VCOBYST
are different.
VCOPWD
1
rw
VCO Power Saving Mode
0
B
Normal behavior
1
B
The VCO is put into a power saving mode and
can no longer be used. Only the Prescaler
Mode is active if previously selected.
VCOSEL
[3:2]
rw
VCO Range Select
The values for the different settings are listed in the
data sheet.
REGENCLR
4
w
Power Regulator Enable Clear
0
B
No action
1
B
Switch off the PLL’s power regulator.
The PLL is not powered (no operation
possible).
REGENSET
5
w
Power Regulator Enable Set
0
B
No action
1
B
Switch on the PLL’s power regulator.
The PLL is powered (operation possible).