%RSD
Percent relative standard deviation. This is a measure of the linearity (using
mathematical regression analysis) of the concentration levels in the calibration
curve for each compound.
Sample loop
The portion of the gas chromatograph through which the inlet flow is directed and
from which the injection is made.
Scan method
This method specifies the masses to be scanned by the mass spectrometer,
length of the run, filament delay, and scan and integration times.
Scan time
In
Full Scan
analysis, this refers to the cumulative time required to make a scan
of all the masses in the range specified. The calculation of scan time includes the
integration time and the points/amu.
SIM
Selected Ion Monitoring
. Mass analysis of one or several ion peaks without
scanning the entire spectrum.
Target ion
The specific ion mass which will be used for quantification or primary identification
of a compound in the library.
Temperature
programmable
Software controlled temperature programming that allows the user to reach
temperatures from 55°C to 200°C in a controlled ramp.
Threshold
A measure of the amplitude of the background noise of the mass spectrometer.
This is determined using the
Noise Check
feature in the tune program.
TIC
Total ion chromatogram. A graph of time verses signal intensity.
TMP
Turbo molecular pump
Torr
Unit of sub-atmospheric pressure. Equivalent to 133.3 pa.
Vacuum
interconnect
valve
The two-part valve which seals the HAPSITE ER manifold, when closed, and
opens it to the vacuum pumps in the Service Module, when open. The vacuum
interconnect valve is powered by a motor within the Service Module, under
direction of the HAPSITE ER.
VSO valve
Voltage sensitive orifice valve. This valve uses voltage applied to the valve to
control the size of its orifice. This in turn controls the flow rate of gas through
HAPSITE ER.
Содержание HAPSITE ER
Страница 1: ...Operating Manual HAPSITE ER 074 471 P1E ...
Страница 2: ...INFICON Two Technology Place East Syracuse NY 13057 9714 ...
Страница 12: ...1 Declaration of Conformity INFICON 12 436 074 471 P1E HAPSITE ER Operating Manual 1 Declaration of Conformity ...
Страница 13: ...INFICON Declaration of Conformity 1 074 471 P1E HAPSITE ER Operating Manual 13 436 ...
Страница 56: ...9 Operate the Instrument in Portable Mode INFICON 56 436 074 471 P1E HAPSITE ER Operating Manual ...
Страница 184: ...12 ER IQ Software INFICON 184 436 074 471 P1E HAPSITE ER Operating Manual ...
Страница 208: ...13 Data Review INFICON 208 436 074 471 P1E HAPSITE ER Operating Manual 4 Double click on the desired data file ...
Страница 226: ...13 Data Review INFICON 226 436 074 471 P1E HAPSITE ER Operating Manual 5 Click Save 6 Click Run ...
Страница 237: ...INFICON Data Review 13 074 471 P1E HAPSITE ER Operating Manual 237 436 2 Check the Search in NIST box ...
Страница 238: ...13 Data Review INFICON 238 436 074 471 P1E HAPSITE ER Operating Manual 3 Click Search ...
Страница 248: ...13 Data Review INFICON 248 436 074 471 P1E HAPSITE ER Operating Manual 2 The report is displayed ...
Страница 250: ...13 Data Review INFICON 250 436 074 471 P1E HAPSITE ER Operating Manual 5 The report opens in Excel ...
Страница 275: ...INFICON Data Review 13 074 471 P1E HAPSITE ER Operating Manual 275 436 6 The identification is displayed on the screen ...
Страница 323: ...INFICON Method Editor 15 074 471 P1E HAPSITE ER Operating Manual 323 436 ...
Страница 330: ...15 Method Editor INFICON 330 436 074 471 P1E HAPSITE ER Operating Manual 2 Select Next until the SIM page is displayed ...
Страница 333: ...INFICON Method Editor 15 074 471 P1E HAPSITE ER Operating Manual 333 436 5 Enter the name of the chemical of interest ...
Страница 349: ...INFICON Method Editor 15 074 471 P1E HAPSITE ER Operating Manual 349 436 The Analyte List is displayed ...
Страница 371: ...INFICON Calibration 16 074 471 P1E HAPSITE ER Operating Manual 371 436 ð Click OK ...
Страница 381: ...INFICON Calibration 16 074 471 P1E HAPSITE ER Operating Manual 381 436 ...
Страница 389: ...INFICON Calibration 16 074 471 P1E HAPSITE ER Operating Manual 389 436 49 Click OK ...
Страница 390: ...16 Calibration INFICON 390 436 074 471 P1E HAPSITE ER Operating Manual 16 3 Definition of Terms in the Calibrate Window ...
Страница 435: ......
Страница 436: ......