19 | Glossary
INFICON
422 / 436
074-471-P1E HAPSITE ER Operating Manual
SDS
Safety data sheet
Multiplier voltage
The voltage applied to the multiplier in the mass spectrometer, which directly
effects the amplitude of signal and background noise.
NEG
Non-evaporable getter. Used for vacuum maintenance.
NIST library
NIST stands for National Institute of Standards and Technology Mass Spectral
Library. This is a library of spectra of compounds which can be searched to
tentatively identify unknown compounds.
Noise Check
An option in the
Tune
program which checks the system for background noise.
The results of the noise check are used to discriminate against baseline noise
during analysis.
Pascal (pa)
Unit of pressure, equal to 1 dyne per cm
2
. Equivalent to 7.5 x 10-3 Torr and 1.45 x
10-4 PSI.
PEEK
A contamination resistant material used for a number of fittings in the HAPSITE
ER.
Phase
The coating on the inside of the gas chromatograph column by which organic
vapors are retained.
PPB
Parts per billion concentration level
PPE
Personal protective equipment
PPM
Parts per million concentration level
PPT
Parts per trillion concentration level
Remote power
Power supplied to the HAPSITE ER and Headspace sample system either from
the Service Module (for the HAPSITE ER) or external AC - 24 V(dc) converter.
Resolution
These settings in the tune program affect the way the mass spectrometer
resolves peaks. Increasing the resolution narrows the peaks in that mass range,
while lowering the resolution will broaden the peaks.
Retention time
The elapsed time from injection of a specific compound onto the column until the
compound exits the column (same as retention time).
Reverse search
A function of the NIST search (tentative unknown identification) library which
allows compounds which are specified in the user library to be identified as part of
the search.
RH
Relative humidity
RIC
Reconstructed ion chromatogram. A presentation of the chromatographic record
which extracts from the TIC and displays the intensity of the ion or ions specified.
Round trip time
The amount of time required to complete a scan of all the masses specified in a
SIM method. This includes the number of masses, integration time, number of
extra measurements, lead in time, and peak width.
RMA
Return material authorization. Returning material cannot be sent back without this
assigned number.
Содержание HAPSITE ER
Страница 1: ...Operating Manual HAPSITE ER 074 471 P1E ...
Страница 2: ...INFICON Two Technology Place East Syracuse NY 13057 9714 ...
Страница 12: ...1 Declaration of Conformity INFICON 12 436 074 471 P1E HAPSITE ER Operating Manual 1 Declaration of Conformity ...
Страница 13: ...INFICON Declaration of Conformity 1 074 471 P1E HAPSITE ER Operating Manual 13 436 ...
Страница 56: ...9 Operate the Instrument in Portable Mode INFICON 56 436 074 471 P1E HAPSITE ER Operating Manual ...
Страница 184: ...12 ER IQ Software INFICON 184 436 074 471 P1E HAPSITE ER Operating Manual ...
Страница 208: ...13 Data Review INFICON 208 436 074 471 P1E HAPSITE ER Operating Manual 4 Double click on the desired data file ...
Страница 226: ...13 Data Review INFICON 226 436 074 471 P1E HAPSITE ER Operating Manual 5 Click Save 6 Click Run ...
Страница 237: ...INFICON Data Review 13 074 471 P1E HAPSITE ER Operating Manual 237 436 2 Check the Search in NIST box ...
Страница 238: ...13 Data Review INFICON 238 436 074 471 P1E HAPSITE ER Operating Manual 3 Click Search ...
Страница 248: ...13 Data Review INFICON 248 436 074 471 P1E HAPSITE ER Operating Manual 2 The report is displayed ...
Страница 250: ...13 Data Review INFICON 250 436 074 471 P1E HAPSITE ER Operating Manual 5 The report opens in Excel ...
Страница 275: ...INFICON Data Review 13 074 471 P1E HAPSITE ER Operating Manual 275 436 6 The identification is displayed on the screen ...
Страница 323: ...INFICON Method Editor 15 074 471 P1E HAPSITE ER Operating Manual 323 436 ...
Страница 330: ...15 Method Editor INFICON 330 436 074 471 P1E HAPSITE ER Operating Manual 2 Select Next until the SIM page is displayed ...
Страница 333: ...INFICON Method Editor 15 074 471 P1E HAPSITE ER Operating Manual 333 436 5 Enter the name of the chemical of interest ...
Страница 349: ...INFICON Method Editor 15 074 471 P1E HAPSITE ER Operating Manual 349 436 The Analyte List is displayed ...
Страница 371: ...INFICON Calibration 16 074 471 P1E HAPSITE ER Operating Manual 371 436 ð Click OK ...
Страница 381: ...INFICON Calibration 16 074 471 P1E HAPSITE ER Operating Manual 381 436 ...
Страница 389: ...INFICON Calibration 16 074 471 P1E HAPSITE ER Operating Manual 389 436 49 Click OK ...
Страница 390: ...16 Calibration INFICON 390 436 074 471 P1E HAPSITE ER Operating Manual 16 3 Definition of Terms in the Calibrate Window ...
Страница 435: ......
Страница 436: ......