9.2
Diagnosis of Electrical Failures
Prior to any repair work on the machine or its drives, the machine has to be secured
against unintentional switching on. Put the machine to its Safety off position as
described in Chapter 2.
Work on the electrical parts of the equipment have to be undertaken by a skilled
electrician or by a trained person under the guidance and supervision of a skilled
electrician in accordance with the electrical engineering regulations.
Failure
Possible Reasons for Failure
Failure Corrective Actions
Motor does not start up
Missing Phase
Check power supply
Faulty Switch or relays
Diagnosis and replacement by
electrician
Emergency Stop
Unlock Emergency Stop Button
Motor stops during
operation
Current too high
Disconnect plug
Power supply circuit breaker
disengaged
Reset circuit breaker or replace
fuse.
Adjust maximum abrasive feeding
(use Amp meter)
Motor is damaged
Check motor
Содержание S210E
Страница 1: ...Operating Manual S210E Your Partner for Mobile Surface Preparation IMPACTSamericas com...
Страница 35: ...Operating Manual S210E 33 8 2 Circuit Diagram...
Страница 40: ...S210E Operating Manual 38 10 2 Blast Wheel Drive Front...
Страница 41: ...Operating Manual S210E 39 10 3 Handle Section...
Страница 42: ...S210E Operating Manual 40 10 4 Separator Top Section...
Страница 43: ...Operating Manual S210E 41 10 5 Abrasive Feeder...
Страница 44: ...S210E Operating Manual 42 10 6 Liner Wheel Housing...
Страница 45: ...Operating Manual S210E 43 10 7 Base Seal Assembly...
Страница 46: ...S210E Operating Manual 44 10 8 Undercarriage...
Страница 47: ......
Страница 48: ...IMPACTS Americas 1384 Bungalow Rd Morris IL 60450 USA 815 941 4800 815 941 4600 Fax www IMPACTSAmericas com...