Both the probe and the concentrator are suitable for indoor operation; they cannot be used outdoors and/or in environments
subject to atmospheric agents.
Association procedure:
Insert the batteries on the probe and press the button on the probe for 5 sec.
If the probe is already previously associated, the LH and RH LEDs will flash alternately, therefore
it is necessary to proceed
with the RF disassociation
(see RF Disassociation operations);
if it is
not associated
the LH LED will start to flash (RH LED off), then continue with the next step of this procedure.
Zone assignment to wireless room probe:
1. make sure to have correctly made the electrical connections between concentrator and boiler and to have inserted the batteries on the
wireless probe;
2. feed the boiler and access the Menu. For more details on menu navigation and access controls, see (Par. 2.6);
3. access with the “Service” credentials;
4. access the Zones Menu;
5. select the zone to which the room probe refers;
6. enter the Definition/Room probe menu;
7. Select Type = RF;
8. set the M3 address of the concentrator to which to associate the wireless probe (the M3 address is defined by the position of the switch-
es on the board inside the concentrator, default 0);
9. press OK (a confirmation window will be displayed with the text "Confirm operation?");
10. accept the confirmation request by pressing OK; then the display will show "Status ..." (association in progress) and Lh LED will flash
on the concentrator (pending association);
11. move to the probe to be associated within 30 seconds and press the central button for 5 seconds. When the LH LED flashes, briefly
press the button again (1 second);
12. once the operation has been completed correctly, the 2 LH and RH LEDs will flash alternately on the probe for 10 sec. to then indicate
on the LH LED the number of the associated zone by flashing, with the RH LED steady. If the operation is not completed correctly, the
two LEDs will flash synchronously for 5 seconds and the display will show the text "Status No-Link" (the operation needs to be repeat-
ed);
13. on Display, when the operation is completed correctly, the room probe status appears as “OK”.
Indications displayed on the "Room probe - Status" menu
The following items appear in the Room probe association window:
-
Status = Err:
configuration error; the association sequence on the concentrator was not successful. Repeat the association sequence.
-
Status = No link:
error on RF association between probe and concentrator; it may also appear with probe battery flat. Check wireless
probe operation and repeat the association sequence.
-
Status = - - :
indicates the wait for configuration; if it is maintained for a long time during the association sequence, check the connec-
tion between the concentrator and boiler.
-
Status = ... :
indicates the mode of association in progress.
-
Status = ok:
indicates the correct association between the wireless probe and the zone to be controlled.
RF disassociation on wireless room probe
Should it be necessary to reset a previous assignment made on the room probe, proceed with the following operation on the room probe:
1. Press and hold the RF Probe button for at least 5s, if it is associated the LH-LEDs and the RH-LEDs will start to flash alternately;
2. At this point, press the button again for 5s and release it when only the LH-LED starts flashing while the RH-LED remains off;
3. Wait until the LH LED stops flashing before making a new association.
By using optional kits such as the concentrator kit for wireless room probes (if necessary to manage a single zone) and any wireless room
probe kit (to manage any other zones up to a maximum of 3), it is possible to activate a room control in central heating / C.H. managed
directly by the boiler.
The central heating / C.H. program will manage two room temperatures (comfort and reduced) in combination with the slots requested
on the central heating / C.H. program (possibly diversified for the 3 zones).
Under these conditions, it will be possible to activate a system flow temperature modulating control so as to limit consumptions (enter
any temperature control class, see table below).
To complete the room control via wireless probes, it is possible to connect the external probe (optional) and activate the control via the
Dominus App (optional).
Remember that the central heating / C.H. demand, in addition to being subject to the central heating / C.H. program and to the tempera-
ture detected by the room probe, it will also be controlled by the contact set up for limit switch micro (terminals 40-41 for single zone).