Error
Code
Anomaly signalled
Cause
Boiler status / Solution
95
Combustion signal
discontinuous
The system detects a discontinuous combustion signal.
The boiler keeps working (1) (2)
96
Clogged flue
This occurs in the event an obstruction is detected in the
flue system.
The boiler does not start (1). If normal
conditions are restored the boiler
restarts without having to be reset
If error 96 appears after the Techni-
cian has made changes on the “flue”
parameters, it is necessary to perform
a “quick calibration”.
98
Block - maximum no.
of software errors
The maximum number of software errors possible has been
reached.
Press the Reset button (1)
99
General block
A boiler anomaly has been detected.
Press the Reset button (1)
121*
Zone 1 device offline
alarm
Low quality or no radio communication between the zone
1 wireless probe and the concentrator.
Check receiver/sensor positioning
Check probe battery (1)
122*
Zone 2 device offline
alarm
Low quality or no radio communication between the zone
2 wireless probe and the concentrator.
Check receiver/sensor positioning
Check probe battery (1)
123*
Zone 3 device offline
alarm
Low quality or no radio communication between the zone
3 wireless probe and the concentrator.
Check receiver/sensor positioning
Check probe battery (1)
125*
Zone 1 room
temperature probe
anomaly
Faulty room sensor (resistor open or short circuit).
Replace room probe (1)
126*
Zone 2 room
temperature probe
anomaly
Faulty room sensor (resistor open or short circuit).
Replace room probe (1)
127*
Zone 3 room
temperature probe
anomaly
Faulty room sensor (resistor open or short circuit).
Replace room probe (1)
138
Screed heater in
progress
Signalling to remote screed heater function devices (except
CAR
V2
).
(1)
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)
(2) The anomaly can only be verified in the list of errors in the “Information” menu
(3) Error displayed only on CAR
V2
(*) Errors visible below zone area icons.