4.1 VARIABLE HEAT OUTPUT
The power data in the table has been obtained with intake-exhaust pipe measuring 0.5 m in length. Gas flow rates refer to net
calorific value below a temperature of 15°C and at a pressure of 1013 mbar.
Victrix Zeus Superior 25
METHANE
(G20)
PROPANE
(G31)
HEAT
OUTPUT
HEAT
OUTPUT
MODULATION
GAS FLOW RATE
BURNER
MODULATION
GAS FLOW RATE
BURNER
(kW)
(kcal/h)
(%)
(m³/h)
(%)
(kg/h)
25,0
21500
D.H.W.
99
2,74
99
2,01
24,0
20640
93
2,63
92
1,93
23,0
19780
86
2,52
85
1,85
22,0
18920
81
2,41
79
1,77
21,0
18060
76
2,29
74
1,68
20,2
17372
HEAT. +
D.H.W.
73
2,20
70
1,62
19,0
16340
69
2,07
62
1,52
18,0
15480
64
1,96
59
1,44
17,0
14620
60
1,85
57
1,36
16,0
13760
57
1,74
55
1,28
15,0
12900
53
1,63
53
1,20
14,0
12040
50
1,52
51
1,12
13,0
11180
46
1,41
48
1,04
12,0
10320
44
1,30
44
0,96
11,0
9460
40
1,20
40
0,88
10,0
8600
38
1,09
37
0,80
9,0
7740
34
0,98
34
0,72
8,0
6880
32
0,87
31
0,64
7,0
6020
30
0,77
26
0,56
6,0
5160
27
0,66
23
0,49
5,0
4300
23
0,55
20
0,41
4,7
4042
22
0,52
18
0,38
3.0
2580
11
0.34
11
0.25
2.3
2012
1
0.26
1
0.19