If there is no Room thermostat, the jumper at the ends of terminals 40-41 must be maintained. In this conditions, a continuous
request from the Room thermostat is simulated
Man functioning mode
With this setting, the central heating / C.H. (as maximum flow set system flow temperature) is manually enabled and will be valid until
the subsequent and different setting.
With single-zone systems, the maximum flow set is also available on the central heating / C.H. set knob; on multi-zone systems it can
be set on the menu Zones\Definition\Regulation.
When the room temperature (if TA present) exceeds that set on the TA, the central heating / C.H. turns off.
Auto functioning mode
By associating a calendar with the relevant zone program, it is possible to determine the time slots for activating the room central heat-
ing / C.H. at a system temperature as set on “Set flow”.
When the room temperature detected by any Room thermostat is lower than required, the central heating / C.H. is activated (only if
requested by the calendar program).
When the room temperature detected by any Room thermostat is higher than required, the room central heating / C.H. is deactivated.
Functioning mode Off
Central heating / C.H. always off.
Anti-Legionella function
If the anti-legionella function is activated (disabled as a standard), the temperature inside the storage tank is brought to 65°C for 30 min-
utes.
Water at temperatures above 50°C can cause severe burns. When the anti-legionella function
is activated, always check the water temperature before any use.
Use with wireless room probes (Optional)
Using Central heating / C.H. through the wireless room probes is the optimal solution for controlling the room temperature.
With room probes configured and enabled, it will be possible to set on the individual zones the room temperature with which to
control the central heating / C.H. ignition; the central heating / C.H. flow set at which the boiler will operate will be regulated to
the ideal temperature for maintaining room comfort, with maximum energy saving.
Man functioning mode
With this setting, the central heating / C.H. is manually disabled and the value set on "Zones\Settings\Set MAN" (room temperature
demand) will be valid until the subsequent and different setting.
When the room temperature exceeds the set room set, the central heating / C.H. turns off.
Auto functioning mode
There are two reference setpoints:
Zones\Settings\Set AUTO Comfort
Zones\Settings\Set AUTO Reduced
By associating a calendar with the relevant zone program, it is possible to determine the time slots when to activate the room tempera-
ture control set as Comfort (Set Auto Comfort); the reduced room temperature control (Set Auto reduced) will be active in the remain-
ing time intervals. The flow set will be automatically calculated according to the room temperature (If the default setting “Room sensor
modul” = YES is maintained).
When the room temperature detected by any Room probe is lower than required, the central heating / C.H. is activated.
When the room temperature detected by any Room probe is higher than required, the room central heating / C.H. is deactivated.
Functioning mode Off
Central heating / C.H. always off.
The presence of the jumper on the TA contact is required when the central heating / C.H. demand needs to be checked using
only the wireless room probes.