67
INS
TALLER
U
SER
M
AINTEN
AN
CE
TECHNI
CI
AN
TECHNI
CAL
D
AT
A
MENU / Information
Menu item
Description
Gas type
Gas type display: NG (Methane), LG (L.P.G.), AP (propane air)
Flame signal
Flame signal display
CH temperature
Flow temperature display
DHW temperature
Storage tank/DHW (Domestic hot water) outlet temperature display
Set CH
This displays the set central heating / C.H. temperature set
Set DHW
Set DHW (Domestic hot water) temperature display
External temperature
(Optional)
Input DHW temperature Not used on this model
CH Return temperature Return temperature display
CH2 temperature
Safety flow probe display
Common flow probe
(Optional)
Duty pump command
Control signal of the pump duty PWM
Flow pump
System flow rate display
Flow rate
Not used on this model
Fan speed
Fan speed display (rpm)
Boiler exhaust temp.
Flue gas temperature display
Solar storage temp.
Not used on this model
Solar collector temp.
Not used on this model
Maintenance withing
This displays the number of days within which maintenance must be carried out. After the days or with the function de-
activated, the line is not displayed
Main board rev. SW
Boiler board sw version display
Firmware version
Display board sw version display
MENU/Historical alarm code
Menu item
Description
Show alarm
This displays the boiler anomaly history. The size of the anomaly history is equal to 10 anomalies.
MENU/ General settings
Menu item
Description
Range
Default
Customised
value
Language
Defines the remote panel operation language
ITA (*)
Display
It is possible to adjust the contrast and lighting of the display. The
lighting (available on two levels) can be automatically selected as fixed
or variable during the boiler operation or user access to the display
Menu access level
Allows the entry of an access code to access the parameter customisa-
tion menus according to ones needs (dedicated to a qualified techni-
cian)
User factory settings
Resets the user parameters to default state
(*) The display leaves the factory set in Italian. To change the display language, see Par. 2.5 in the “USER” chapter, under “Changing the
display language”.
In case the user restores the factory conditions through
"Menu/General settings/User factory settings"
, the menu will appear in Eng-
lish. Proceed in the following way to restore the desired display language:
- Enter
Menu/General setting/Language
.
- Select the desired language from those available and press OK.