Victrix Zeus Superior 25
Gas type
CO
2
to nominal Q.
CO
2
to ignition Q.
CO
2
to minimum Q.
G20
8.8% (± 0,5)
8.8% (± 0,5)
8.8% (± 0,5)
G31
10.3% (± 0,5)
9.9% (± 0,5)
9.9% (± 0,5)
Gas type
O
2
at Nominal Q.
O
2
at Ignition Q.
O
2
at Minimum Q.
G20
5,2% (± 0,9)
5,2% (± 0,9)
5,2% (± 0,9)
G31
5,2% (± 0,7)
5,6% (± 0,7)
5,8% (± 0,7)
Victrix Zeus Superior 30
Gas type
CO
2
to nominal Q.
CO
2
to ignition Q.
CO
2
to minimum Q.
G20
8.8% (± 0,5)
8.8% (± 0,5)
8.8% (± 0,5)
G31
10.5% (± 0,5)
10.3% (± 0,5)
10.3% (± 0,5)
Gas type
O
2
at Nominal Q.
O
2
at Ignition Q.
O
2
at Minimum Q.
G20
5,2% (± 0,9)
5,2% (± 0,9)
5,2% (± 0,9)
G31
5,2% (± 0,7)
5,2% (± 0,7)
5,2% (± 0,7)
Victrix Zeus Superior 35
Gas type
CO
2
to nominal Q.
CO
2
to ignition Q.
CO
2
to minimum Q.
G20
8.8% (± 0,5)
8.8% (± 0,5)
8.8% (± 0,5)
G31
10.3% (± 0,5)
10.3% (± 0,5)
10.3% (± 0,5)
Gas type
O
2
at Nominal Q.
O
2
at Ignition Q.
O
2
at Minimum Q.
G20
5,2% (± 0,9)
5,2% (± 0,9)
5,2% (± 0,9)
G31
5,2% (± 0,7)
5,2% (± 0,7)
5,2% (± 0,7)
In addition to yearly maintenance, one must also check the energy efficiency of the thermal system, with frequency and proce-
dures that comply with the indications of the technical regulations in force.