Error
Code
Anomaly signalled
Cause
Boiler status / Solution
59
Electric power supply
mains frequency
anomaly
The board detects a main supply voltage frequency anoma-
ly.
The boiler does not start (1)
60
Anomaly pump
blocked
The pump is stopped due to one of the following causes:
Impeller blocked, electrical fault.
Try to unblock the pump as described
in the relative section. If normal
conditions are restored the boiler
restarts without having to be reset (1)
61
Air in circulator
pump anomaly
Air is detected inside the pump; the pump cannot work.
Vent the pump and the central heating
circuit. If normal conditions are
restored the boiler restarts without
having to be reset (1)
62
Complete calibration
required
Missing calibration is detected by the P.C.B. It may occur in
the event the P.C.B. is replaced or if the parameters are al-
tered in the air / gas section, thus requiring “complete cali-
bration”.
The boiler does not start (1)
72
Fast calibration
required
The P.C.B. detects that some parameters have been altered,
thus requiring “fast calibration”.
The boiler does not start (1)
73
High deviation
between flow probe
and safety flow probe
Faulty flow sensor or not correctly inserted.
If normal conditions are restored the
boiler restarts without having to be
reset (1)
74
Safety flow probe
anomaly
The board detects an anomaly on the NTC safety flow
probe.
The boiler does not start (1)
77
Combustion control
anomaly
Out of range current is detected on the gas valve.
The boiler does not start (1)
78
Combustion control
anomaly
High current on the gas valve is detected.
The boiler does not start (1)
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)