MENU/Service/Domestic Hot Water
Menu item
Description
Range
Default
Customised
value
Boiler control input
Set the type of board input on which to
activate the storage tank control
ntc: storage tank control performed
via NTC probe
ntc:
dig: storage tank control performed
via contact (not used on this model)
ntc+dig: storage tank control per-
formed by summing the probe read-
ing and the enabling contact (not used
on this model)
DHW hysteresis
Set the storage tank control hysteresis
and temperature
hyster. 0: 3k control hysteresis and
flow = set +25k
hyster. 1
hyster. 1: 3k control hysteresis and
flow correlated to boiler power
hyster. 2: 10k control hysteresis and
flow correlated to set
hyster. 3: 5k control hysteresis and
flow fixed at 85°C
hyster. 4: hysteresis and flow settable
on parameters below the item
Boil.water temp. hyster. 4
Set the storage tank flow temperature
for hysteresis type 4
35 ÷ 85
70°C
Diff. prec. with hyster. 4
Set the storage tank control hysteresis
for type 4 hysteresis
2 ÷ 10
6 °C
DHW flow regulator
Not used on this model
Open / 8 l/min / 10 l/min / 12 l/min / 14
l/min / 16 l/min / Auto / Auto H / Auto
T / Auto HT
Open [0]
DHW min set
Set minimum DHW (Domestic hot
water) set limit available to user
10 ÷ 65
10°C
DHW max set
Set maximum DHW (Domestic hot
water) set limit available to user
10 ÷ 65
60°C
Antilegionella
Anti-legion.cycle time: Sets the an-
ti-legionella function intervention
time
00:00 ÷ 24:00
02:00
Anti-legion.cycle day: Sets the day(s)
of activation of the anti-legionella
function
None ... All
None
MENU/Service/Central Heating
Menu item
Description
Range
Default
Customised
value
CH min set
Set minimum central heating / C.H. set limit available
20 ÷ 85
20°C
CH max set
Set maximum central heating / C.H. set limit available
20 ÷ 85
85°C
Edit external probe
Sets correction factor on external probe reading
-9 ÷ 9
0 °C
Edit max common flow
probe
Sets the maximum limit for boiler flow set correction from system
flow probe reading (Optional)
0 ÷ 15
5°C