MENU/Service/Boiler/Flue
Menu item
Description
Range
Default
Customised
value
Length
Sets flue length
min / med /
max
Min
Enable klapet valve
Not used on this model
Complete /
Partial
Com-
plete
A change in these parameters will cause the boiler block signalled with E72; to reset E72, a quick calibration must be activated.
MENU/Service/Boiler/Timers
Menu item
Description
Range
Default
Customised
value
Anti heating cycles
Central heating / C.H. anti-cycle timer set
0 ÷ 840
180
seconds
Heating ramp
Set central heating ramp timer
0 ÷ 840
180
seconds
RT request delay
Set delay timer requested by TA
0 ÷ 600
0 seconds
Solar delay
Not used on this model
0 ÷ 300
0 seconds
Waiting time priority
Not used on this model
0 ÷ 100
0 seconds
Antilegionella stop
Sets anti-legionella end temp
0 ÷ 255
180
minutes
Boiler end of precedence Not used on this model
MENU/Service/Boiler/Circulator
Menu item
Description
Range
Default
Customised
value
Mode
Sets the central heating / C.H. pump
operation mode
Interm. = in winter “mode” the pump
is managed according to the room
control request.
Interm.
Cont. = in “Winter” mode the pump is
always powered and is therefore al-
ways in operation
Max speed
Sets the maximum pump operating
speed in central heating / C.H.
1 ÷ 9
9
Min speed
Sets the minimum pump operating
speed in central heating / C.H.
1 ÷ 9
6
Delta t
This defines the type of speed control
of the pump in central heating / C.H.
Delta t = 0: head proportional to the
power supplied by the burner
15°C
Delta t = 5…25 : constant Delta t oper-
ation (at the set value)