MENU/Service/Special function/Screed heater
Menu item
Description
Range
Default
Customised
value
En. screed heater
Activates the function with Yes select-
ed and the advanced end if No is se-
lected
No - Yes
No
Minimum flow set
It is possible to set the minimum flow
temperature at screed heater function
start
20 ÷ 45 (°C)
25°C
Maximum flow set
It is possible to set the maximum flow
temperature delivered during the
screed heater function
25 ÷ 55 (°C)
45°C
Time spent set min
It is possible to set the days of stay at
minimum flow set during the screed
heater function
1 - 7 (days)
3 gg
Climb gradient
It is possible to set the ascent variation
speed from minimum flow set to max-
imum flow set during the screed heat-
er function
3 - 30 (°C/day)
30 °C/g
Time spent set max
It is possible to set the days of stay at
maximum flow set during the screed
heater function
1 - 10 (days)
4 gg
Descent gradient
It is possible to set the descent varia-
tion speed from maximum flow set to
minimum flow set during the screed
heater function
3 - 30 (°C/day)
30 °C/g
Status
This displays the screed heater func-
tion progress
Off = deactive function
Min = function active with stay time
at minimum flow set
Up = function active with increase
from minimum flow set to maximum
flow set
Max = function active with stay time
at maximum flow set
Down = function active with decrease
from maximum flow set to minimum
flow set
Holding time T max
Tis displays the stay time at maximum
screed heater temperature (h)
( h)
Function duration in
days
This displays the time remaining until
the end of the function in days
(days)
Function duration in
hours
This displays the time remaining in
hours until the end of the function (to
be added to the days of the previous
item)
(h)
MENU/Service/Maintenance
Menu item
Description
Range
Default
Customised
value
Select number of months Sets the number of months for scheduled maintenance
Off - 36
Off