2.6 PARAMETERS AND INFORMATION MENU
Navigation diagram within the boiler display
There are 3 Settings menus (Fig. 44):
DHW (Domestic hot water)
: accessible by pressing the domestic hot water button (2);
Zones
: accessible by pressing the zone button (3);
General settings menu
: accessible by pressing the menu button (18).
Some menu settings appear only when the options are actually connected and working.
“DHW (Domestic hot water)” Menu.
Press the “DHW (Domestic hot water)” button to access a list of variables that enable you to customise use of the DHW (Domestic hot
water).
Hereunder is a list of available menus:
DHW settings
Menu item
Description
Range
Default
Customised
value
DHW control
Boiler = DHW (Domestic hot water) control managed from boiler panel
Remote = DHW (Domestic hot water) control managed by CAR v2
Temperature
Temperature read by the DHW probe
Boost function (*)
Sets the DHW (Domestic hot water) boost function management:
Off-On-Auto
Off
Boost: Off = always off
ON = always on
Auto = managed as required by the DHW (Domestic hot water) pro-
gram
Set management (*)
Sets the DHW (Domestic hot water) set control mode:
Auto-Man
Man
Auto = the DHW (Domestic hot water) set will be controlled at two
levels, according to the DHW (Domestic hot water) program.
Manual = the DHW (Domestic hot water) set will always be fixed at the
manual value (regardless of the DHW (Domestic hot water) program)
Set comfort
Sets comfort set (comfort set will be active during the active time slots
of the DHW (Domestic hot water) program if “Set management =
Auto” is selected)
10 ÷ 60 °C
50°C
Set economy
Sets reduced set (economy set will be active during the NON active
time slots of the DHW (Domestic hot water) program if “Set manage-
ment = Auto” is selected)
10 ÷ 60 °C
30°C
Set manual
Sets manual set (manual set will be active 24 hours a day if “Set man-
agement = Man” is selected)
10 ÷ 60 °C
10°C
(*) See DHW (Domestic hot water) paragraph