2.8 PREPARATION OF ENGINE EXTENDED
SHUTDOWN
2-8-02
- Starting air systems
- If the engine is to be disconnected from the starting air reservoir, make certain
that the inlet and outlet ports are sealed to prevent dirt and moisture from entering
the system.
- Intake and exhaust systems
- Place silica gel in the intake air duct and seal the duct as required to keep out
about 60-80 grams of dirt and moisture. Make certain that a conspicuous tag is
attached so that the seal and gel will be removed before the engine is put back
into service.
- Seal the turbocharger air inlet.
- Seal the exhaust pipe.
- Accessories
- Seal the inlet and outlet ports of the starting air reservoir if the lines are
disconnected.