This document is property of NIIGATA POWER SYSTEMS CO., LTD. It must be neither reproduced nor communicated nor published without permission.
S E C T I O N
5
- M A I N T E N A N C E
5.4 ABNORMAL SITUATION
5-4-03
Trouble phenomenon and probable cause
→
Remedy
(3)
Emission of mist pipe.
a) Moving parts such as
pistons are about to be
seized.
Immediately stop the engine.
- As there is a possibility of
occurrence of explosion, do not
immediately open inspection doors
after the engine has stopped.
Wait for about 15 minutes before
opening inspection door.
a) Tactually check the following parts:
Bearings, connecting rod big ends,
cylinder liner bottoms (with pistons
placed at top dead center). etc.
Compare with recent running record
(pressure, temperature) and find
out sources of abnormality.
b) Stuck piston rings
b) Excessive oil temperature:
Check flow rates of lub. oil system
and cooling water system.
Check if the lub. oil is matched
with the used fuel.