SmartPLC DataLine with EtherNet/IP device interface
91
>
Configure the IP parameters manually
41607
To manually configure the IP parameters of the EtherNet/IP interface:
1 Select the menu page
►
>
>
►
Select [Fieldbus] tab.
2 Activate the manual configuration
►
From the list [IP mode], select the value
Static
(→
Notes on IP settings
(→ S.
>
The IP address fields [IP address], [Subnet mask] and [Gateway address] can be edited.
3 Set the IP parameters of the EtherNet/IP interface
►
Set the following parameters as required:
– [IP address]
– [Subnet mask]
– [Gateway address]
4 Save the changes
►
Press [Accept] button.
>
Selected values are applied.
>
Configure the IP parameters automatically
41603
In order to obtain the interface parameters automatically via DHCP or BOOTP, the device
must be connected to a DHCP or BOOTP server.
► Connect the EtherNet/IP interfaces (X6/X7) to a DHCP/BOOTP server.
1 Select the menu page
►
>
>
►
Select [Fieldbus] tab.
2 Select the configuration method
►
From the list [IP mode], select either
DHCP
or
BOOTP
.
3 Save the changes
►
Press [Accept] button.
>
The device receives the IP parameters from a DHCP or BOOTP server.
>
Selected value is applied.
>
[IP address], [Subnet mask] and [Gateway address] show the current values.