SmartPLC DataLine with EtherNet/IP device interface
162
Slot
Description
Value range
Length
[words]
1
Digital input data of single or
A slaves, connected to AS-i
master 1
Empty module = Module is disabled
0
01 ... 03 = Module is active with slaves 1(A) ... 3(A), AS-i Master 1
1
01 ... 07 = Module is active with slaves 1(A) ... 7(A), AS-i Master 1
2
01 ... 11 = Module is active with slaves 1(A) ... 11(A), AS-i Master 1
3
01 ... 15 = Module is active with slaves 1(A) ... 15(A), AS-i Master 1
4
01 ... 19 = Module is active with slaves 1(A) ... 19(A), AS-i Master 1
5
01 ... 23 = Module is active with slaves 1(A) ... 23(A), AS-i Master 1
6
01 ... 27 = Module is active with slaves 1(A) ...27(A), AS-i Master 1
7
01 ... 31 = Module is active with slaves 1(A) ... 31(A), AS-i Master 1
8
Mapping of the digital input/output data:
→
Mapping of the digital input/output data
(
>
Slot 2 – Digital output data single or A slaves, AS-i master 1
41621
Slot
Description
Value range
Length
[words]
2
Digital output data of single
or A slaves, connected to
AS-i master 1
Empty module = Module is disabled
0
01 ... 03 = Module is active with slaves 1(A) ... 3(A), AS-i Master 1
1
01 ... 07 = Module is active with slaves 1(A) ... 7(A), AS-i Master 1
2
01 ... 11 = Module is active with slaves 1(A) ... 11(A), AS-i Master 1
3
01 ... 15 = Module is active with slaves 1(A) ... 15(A), AS-i Master 1
4
01 ... 19 = Module is active with slaves 1(A) ... 19(A), AS-i Master 1
5
01 ... 23 = Module is active with slaves 1(A) ... 23(A), AS-i Master 1
6
01 ... 27 = Module is active with slaves 1(A) ...27(A), AS-i Master 1
7
01 ... 31 = Module is active with slaves 1(A) ... 31(A), AS-i Master 1
8
Mapping of the digital input/output data:
→
Mapping of the digital input/output data
(