10BSet-up
57BConfiguration
11-15
End configuration
Now all slaves are present on the bus with the correct address.
But the error message (the sign "!") keeps on flashing and the LED [
CONF/PF
]
lights?
Cause: the controllere has detected all slaves on the bus but the slaves are not
yet – at least not all – in the "List of projected slaves" LPS.
So: the error message "configuration error" is displayed as long as there is a dif-
ference between the detected and configured slaves.
Remedy: enter all detected slaves in the configuration list at the push of a button
in the mode "Quick Setup".
i
Tip
Password level 1 required
→
page 11-23, chapter "Password setting"
E25 ASi1
Config. Error
M
M
E
E
N
N
U
U
1/2
▲
!
▼
U
U
S
S
E
E
R
R
1.
> The display on the left appears instead of the
ifm
start
screen: "Configuration error"
►
Press the [
MENU
] button
PLC Setup
Slave Lists
Address Slave
O
O
K
K
1
▲
!
▼
E
E
S
S
C
C
2.
> The
controllere shows the last used menu item
►
Press [
▲
] to scroll to "Slave Lists"
Reason: check the configuration made so far in the list
of detected slaves LDS.
PLC Setup
Slave Lists
Address Slave
O
O
K
K
1
▲
!
▼
E
E
S
S
C
C
3.
►
Press [
OK
] to select "Slave Lists"
Содержание Ecomat 300 AC1307
Страница 10: ......
Страница 14: ......
Страница 16: ......
Страница 18: ......
Страница 30: ......
Страница 32: ......
Страница 62: ......
Страница 96: ......
Страница 114: ......
Страница 175: ...13BScale drawing 14 1 14 Scale drawing 107 97 86 LED 62 2 1 3 Figure dimensions of the controllere ...
Страница 176: ......
Страница 180: ......
Страница 206: ......
Страница 208: ......
Страница 215: ......