Manual slave addressing
The old slave
address is not
0?
The automatic procedure described above (
→
page 11-8) however only works
without problems if the slaves to be connected have the address 0! If the slaves
have already been used in another system the slaves will probably already have
another address. In such a case, the controllere does not react to the connection
of the new slave.
►
Remove these slaves from the system.
In the following section we will show you how the addresses of the units can be
changed.
E25 ASi1
Config. Error
M
M
E
E
N
N
U
U
1/2
▲
!
▼
U
U
S
S
E
E
R
R
►
End automatic addressing
Scroll back to the start screen (
→
screen) by pressing
[
ESC
] several times.
You would like to integrate a slave in the AS-i bus which has already been pro-
grammed an address but now needs a new address?
Prerequisites:
•
Neither the "old" nor the new address of the slave must already be assigned
on the bus.
•
There must be no slave with the address 0 connected on the AS-i bus.
►
If necessary, remove the already existing slave with the correct "old" address
from the bus temporarily.
►
Install or activate the new slave on the bus.
i
Tip
Password level 1 required
→
page 11-23, chapter "Password setting"
E25 ASi1
Config. Error
M
M
E
E
N
N
U
U
1/2
▲
!
▼
U
U
S
S
E
E
R
R
1.
> The display on the left appears instead of the
ifm
start
screen: "Configuration error"
> LED
[
CONF/PF
] lights
Cause: there is (at least) one new slave on the bus which
the controllere does not yet have in its projection list.
Note
: description of the error message
→
►
Press [
MENU
]
Содержание Ecomat 300 AC1307
Страница 10: ......
Страница 14: ......
Страница 16: ......
Страница 18: ......
Страница 30: ......
Страница 32: ......
Страница 62: ......
Страница 96: ......
Страница 114: ......
Страница 175: ...13BScale drawing 14 1 14 Scale drawing 107 97 86 LED 62 2 1 3 Figure dimensions of the controllere ...
Страница 176: ......
Страница 180: ......
Страница 206: ......
Страница 208: ......
Страница 215: ......