3: D
EVICE
A
DDRESSES
D8040-D8047 Analog Input Value
The analog input values (0 to 10 VDC) to the analog input terminals are converted to digital values (0 to 1000) and stored to the
corresponding special data registers.
D8040=AI0, D8041=AI1, D8042=AI2, D8043=AI3, D8044=AI4, D8045=AI5, D8046=AI6, D8047=AI7
D8050-D8073, D8134-D8145 High-speed Counter
These special data registers are used with the high-speed counter function and the frequency measurement function.
For details on the SmartAxis Pro/Lite high-speed counter, see Chapter 5 “Special Functions” – “High-speed Counter” in the FT1A
Series Pro/Lite User's Manual. For details on the SmartAxis Touch high-speed counter, see Chapter # “Project Settings” – “#.##
Functions” – “High-speed Counter” in the FT1A Series Touch User's Manual.
D8077 Out of Analog Input Range Status
When an analog input value is 11V or higher, the corresponding bit of D8077 turns on. When an analog input value is lower than
11V, the corresponding bit of D8077 turns off.
The assignment of each analog input is as follows.
D8078-D8083 MAC Address (Read only)
MAC address of the SmartAxis is stored to the special data registers in hexadecimal as shown below.
Example) MAC address: AA-BB-CC-DD-EE-FF
D8078=AAh, D8079=BBh, D8080=CCh, D8081=DDh, D8082=EEh, D8083=FFh
D8084-D8087 IP Address (Current Data) Read only
IP address of the SmartAxis is stored to the special data registers as shown below.
Example) IP address: aaa.bbb.ccc.ddd
D8084=aaa, D8085=bbb, D8086=ccc, D8087=ddd
D8088-D8091 Subnet Mask (Current Data) Read only
Subnet mask of the SmartAxis is stored to the special data registers as shown below.
Example) Subnet mask: aaa.bbb.ccc.ddd
D8088=aaa, D8089=bbb, D8090=ccc, D8091=ddd
D8092-D8095 Default Gateway (Current Data) Read only
Default gateway of the SmartAxis is stored to the special data registers as shown below.
Example) Default gateway: aaa.bbb.ccc.ddd
D8092=aaa, D8093=bbb, D8094=ccc, D8095=ddd
D8104 RS232C Control Signal Status (Port 2 and Port 3)
RS232C control signal status of port 2 and port 3 is stored to D8104.
0
2
0
1
0
D8077
0
3
7
8
Bit
15
Bit
0
Bit
Bit
4
5
6
0
0
0
0
Analog Input 0
Analog Input 1
Analog Input 2
Analog Input 3
Analog Input 4
Analog Input 5
Analog Input 6
Analog Input 7
00:
Both DSR and DTR are off
01:
DSR is off, DTR is on
10:
DSR is on, DTR is off
11:
Both DSR and DTR are on
0
2
0
1
0
D8104
0
3
Port 2
Port 3
7
8
Bit
15
Bit
0
Bit
Bit
Bit
Содержание microsmart pentra
Страница 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Страница 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...