User Communication Receive Instruction Dialog Box in WindLDR
Selections and Devices in Receive Instruction Dialog Box
Receive Format
Receive format, designated by source device S1, specifies data registers to store received data, data digits for storing data, data
conversion type, and repeat cycles. A start delimiter and an end delimiter can be included in the receive format to discriminate
valid incoming communication. When some characters in the received data are not needed, “skip” can be used to ignore a
specified number of characters. BCC code can also be appended to the receive format to verify the received data. One RXD
instruction can receive 200 bytes of data at the maximum.
S1 (Source 1)
Note:
Total byte count of the receive format is shown in S1 of RXD instruction on the ladder diagram of WindLDR.
Type
TXD
Transmit instruction
RXD
Receive instruction
Port
Port 2 - Port 3
Receive user communication to port 2 (RXD2) through port 3 (RXD3)
S1
Source 1
Enter the receive format in this area.
The receive format can include a start delimiter, data register to store incoming data, constants, end delimiter,
BCC, and skip.
D1
Destination 1
Receive completion output can be an output or internal relay.
D2
Destination 2
Receive status register can be data register D0-D1998.
The next data register stores the byte count of received data.
Receive
Format
Device
Receive
Digits
(Bytes)
Conversion
Type
Repeat
BCC
Calculation
Calculation
Start
Position
Skip
Bytes
Delimiter
Data
Register
D0-D1999
1-4
1-5
1-2
A:ASCII to Binary
B:ASCII to BCD
–:No conversion
1-99
—
—
—
Hex
ASCII
Start
Delimiter
00h-FFh
1 to 5 bytes
—
No conversion
—
—
—
—
End
Delimiter
00h-FFh
—
No conversion
—
—
—
—
Constant
for
Verification
00h-FFh
—
No conversion
—
—
—
—
BCC
—
1-2
A:Binary to ASCII
–:No conversion
—
X:XOR
A:ADD
C:Add-2comp
M:Modbus ASCII
M:Modbus RTU
1-15
—
Skip
—
—
—
—
—
—
1-99
Содержание microsmart pentra
Страница 1: ...FT1A SERIES FC9Y B1382 Ladder Programming Manual ...
Страница 6: ...Preface 5 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 104: ...7 DATA COMPARISON INSTRUCTIONS 7 10 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 122: ...8 BINARY ARITHMETIC INSTRUCTIONS 8 18 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 138: ...10 SHIFT ROTATE INSTRUCTIONS 10 12 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 162: ...11 DATA CONVERSION INSTRUCTIONS 11 24 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 188: ...12 CALENDAR COMPARISON INSTRUCTIONS 12 26 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 198: ...15 REFRESH INSTRUCTIONS 15 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 202: ...16 INTERRUPT CONTROL INSTRUCTIONS 16 4 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...
Страница 266: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC5A MICROSMART USER S MANUAL FC9Y B1273 ...
Страница 318: ...25 USER COMMUNICATION INSTRUCTIONS 25 22 FT1A SMARTAXIS USER S MANUAL FT9Y B1382 ...