![IDEC FS1A-C11S Скачать руководство пользователя страница 318](http://html.mh-extra.com/html/idec/fs1a-c11s/fs1a-c11s_user-manual_617376318.webp)
LOGIC
5-270
Timing chart (Logic 105)
Safety input1:X0
Start input 2: X17
(Control)
Monitor output for
safety input 1: Y4
Safety input1:X1
note 1)
note 1)
Safety output 1: Y0
Safety input 3:
X4, X5
Safety input 2:
X2, X3
Safety input 4:
X6, X7
Safety input 5:
X10, X11
Start input 1: X16
(Manual)
Monitor output for
Safety output 1: Y12
Safety output 2: Y1
Monitor output for
Safety output 2: Y13
Safety output 3: Y2
Monitor output for
Safety output 3: Y17
Safety output 4: Y3
Monitor output for
Safety output 4: Y20
State monitor output 3:
Y16
Max. 6s
Initialization
Max. 0.1s
Min. 0.1s
0.1s~5s
Monitor output for safety
input 2: Y5
Monitor output for
safety input 3: Y6
Monitor output for
safety input 4: Y7
Monitor output for
safety input 5: Y10
OFF delay time
OFF delay time
Max. 0.1s
Safety
output
1 to 4
ON
Safety
output
1 to 4
ON
Safety
output
1, 2
ON
Safety
output
3
ON
Safety
output
4
ON
Power
ON
Note 1) Input monitor error detection time is 0.1s.
About safety inputs that are not described in this chart, input monitor error detection time is as follows.
The time of dual channel safety input (X2 to X11) is 0.1s.
Refer to the following “Logic functions” for more details.
Содержание FS1A-C11S
Страница 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Страница 2: ......
Страница 10: ......
Страница 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Страница 38: ...INSTALLATION AND WIRING 3 8 ...
Страница 48: ...BASIC OPERATIONS 4 10 ...
Страница 78: ...LOGIC 5 30 ...
Страница 90: ...LOGIC 5 42 ...
Страница 102: ...LOGIC 5 54 ...
Страница 116: ...LOGIC 5 68 ...
Страница 154: ...LOGIC 5 106 ...
Страница 231: ...LOGIC 5 183 Chapter 5 ...
Страница 307: ...LOGIC 5 259 Chapter 5 ...
Страница 319: ...LOGIC 5 271 Chapter 5 ...
Страница 331: ...LOGIC 5 283 Chapter 5 ...
Страница 386: ...LOGIC 5 338 ...