![IDEC FS1A-C11S Скачать руководство пользователя страница 114](http://html.mh-extra.com/html/idec/fs1a-c11s/fs1a-c11s_user-manual_617376114.webp)
LOGIC
5-66
Timing chart (Logic 11d)
Example: Manual start input (X16) is used.
(Safety input 2, 3 and 4 are all ON and muting input 2 is OFF in this chart.)
Not
e 1) When “Safety input 1” is turned OFF before “Muting input 1” is turned ON, muting function is not effective and
all of “Safety output” are not turned ON. “Safety input 2” and “Muting input 2” is as well.
Note 2) Input monitor error detection time is 3s.
About safety inputs that are not described in this chart, input monitor error detection time is as follows.
The time of dual channel safety input (X0, X1, X4, and X5) is 0.1s.
The time of muting input (X6, X7) is 3s.
The time of dual channel direct opening input (X10 to X13) is 0.5s.
Refer to the following “Logic functions” for more details.