PRODUCT SPECIFICATIONS
2-11
C
h
a
p
te
r 2
Monitor output specifications
Output type
Source output (N channel MOSFET)
Rated output voltage
Power supply voltage
Minimum output voltage
Power supply voltage - 2.0V
Number of outputs
11 (Y4, Y5, Y6, Y7, Y10, Y11, Y12, Y13, Y14, Y15, Y16)
Maximum output current
Point
20mA maximum
total
220mA maximum
Leakage current
0.1mA maximum
Cable length
Note1
100m maximum (total wiring length per 1output)
Note1. For cables longer than 30m between SafetyOne and connected devices, use grounded
shielded cables to assure electromagnetic compatibility.
Monitor output equivalent circuit
Internal
circuit
Logic
circuit
Yn
V-
V+
The specifications of the monitor outputs change depending on the Logic selected. See further
information in “Chapter 5 LOGIC”. But basic specifications are the same.
Warning
Do not use monitor outputs for safety related purposes. This may cause a loss of safety
functions in case of failure of the SafetyOne or peripherals.
Caution
Use an IEC60127-approved fuse on the monitor output circuit. (This is required for equipment
incorporating SafetyOne that is destined for Europe.)
Ex. Fast-Acting fuse, Amp rating 0.125A, Voltage rating 250V
Содержание FS1A-C11S
Страница 1: ...FS9Z B1218 FS1A C11S Safety Controller SafetyOne User s manual ...
Страница 2: ......
Страница 10: ......
Страница 16: ...PRODUCT SPECIFICATIONS 2 4 Dimensions Detail of locking ring Locking ring ...
Страница 38: ...INSTALLATION AND WIRING 3 8 ...
Страница 48: ...BASIC OPERATIONS 4 10 ...
Страница 78: ...LOGIC 5 30 ...
Страница 90: ...LOGIC 5 42 ...
Страница 102: ...LOGIC 5 54 ...
Страница 116: ...LOGIC 5 68 ...
Страница 154: ...LOGIC 5 106 ...
Страница 231: ...LOGIC 5 183 Chapter 5 ...
Страница 307: ...LOGIC 5 259 Chapter 5 ...
Страница 319: ...LOGIC 5 271 Chapter 5 ...
Страница 331: ...LOGIC 5 283 Chapter 5 ...
Страница 386: ...LOGIC 5 338 ...