ICT ICT-2U4 Скачать руководство пользователя страница 54

54 

Innovative Circuit Technology Ltd. 

ICT LIMITED WARRANTY  

 
The warranty period on ICT products is two (2) years from date of purchase from an authorized ICT reseller or OEM 
with valid proof of purchase, or from date of shipment from the ICT manufacturing facility. The warranty period for 
a repaired product or part is ninety (90) days or the remainder of the unexpired term of the new product warranty 
period,  whichever  is  greater.  Repair  or  replacement  of  a  defective  product  or  part  does  not  extend  the  original 
warranty coverage period.  
 
ICT Limited Warranty is only intended for the benefit of the original purchaser and user of this product. This Warranty 

is not transferable or assignable without the prior written permission of ICT. ICT’s sole obligation and liability under 

this  warranty  is  limited  to  either  repairing  or  replacing  defective  products  at  the  sole  discretion  of  ICT.  When 
repairing or replacing the products, ICT may use products or parts that are new, equivalent to new or re-conditioned. 
Parts  repaired or  replaced during  the warranty period will be under  warranty for  the remainder of  the warranty 
period.  
 

No  claim  will  be  accepted  unless  written  notice  of  the  claim  is  received  by  ICT  in  accordance  with  ICT’s  Return 

Material  Authorization  (RMA)  procedure,  as  soon  as  reasonably  possible  after  the  defect  is  discovered.  A  valid 
product serial number must be provided with the RMA claim to prove eligibility. The RMA form is available on the 
ICT website a

www.ict-power.com/support/warranty-repair/

 

 

The  Purchaser shall  at  their  own  risk  and  cost  return  the  defective  product  to  ICT’s  factory  or  designated  repair 

center once  an  RMA  is  issued  by  ICT.  Return  of  the  products  to  the  customer  after  repair  is  completed  shall  be 
prepaid by ICT unless otherwise mutually agreed between the parties. Products shipped to ICT which have incurred 
freight damage will not be covered by this Warranty and any repairs or replacement parts, components or products 
needed will be invoiced in the full current price amount 

and returned freight collect to Purchaser. It is the Purchaser’s 

responsibility to check the product upon receipt for any damage during shipping and to contact the carrier or shipper 
regarding  such  damage.  Product  that  is  returned  as  defective,  which  is  determined  to  operate  within  published 
specifications will be returned to the Purchaser freight collect.  
 
ICT  assigns  to  Purchaser  any  warranties  which  are  made  by  manufacturers  and  suppliers  of  components  of,  or 
accessories for, the ICT product and which are assignable. ICT makes no representations as to the effectiveness or 
extent of such warranties, assumes no responsibility for any matters which may be warranted by such manufacturers 
or suppliers and extends no additional coverage under this Warranty to such components or accessories. 
 
In no event shall ICT be liable for any special, indirect or consequential damages such as, but not limited to, loss of 
use,  business  or  goodwill,  loss  of  revenue,  or  loss  of  profits,  which  may  result,  either directly  or  indirectly,  from 
defects in products provided by ICT.  
 
This Warranty will be void if the product has been subjected to misuse, neglect, accident, exposure to environmental 

conditions not conforming to the products’ limits of operation, improper installation or maintenance, improper use 

of  an  electrical  source,  defects  caused  by  sharp  items  or  by  impact  pressure,  a  force  majeure  event,  has  been 
modified or repaired by anyone other than ICT or its authorized representative, has been subjected to unreasonable 
physical, thermal or electrical stress, improper maintenance, or causes external to the unit including but not limited 
to  general  environmental  conditions  such  as  rust,  corrosive  atmospheres,  sustained  temperatures  outside  the 
specified operating range of the equipment, exposure to power surges and/or electrical surges, improper grounding, 
mold or dust, animal or insect damage, water damage or immersion in liquid of any kind, or if the serial number has 
been altered, defaced, or removed.  
 
ICT does not control the installation and use of any ICT product. Accordingly, it is understood this does not constitute 
a warranty of performance or a warranty of fitness for a particular purpose. This Warranty represents the entire 
agreement between ICT and Purchaser with respect to the subject matter herein and supersedes all prior verbal or 
written communications, representations, understandings, or agreements relating to this subject.

 

 
 
 
 
 
 
 

INNOVATIVE CIRCUIT TECHNOLOGY LTD. 

26921 Gloucester Way 

Langley, British Columbia, Canada   V4W 3Y3 

604.856.6303  

F

 604.856.6365   

www.ict-power.com

 

Содержание ICT-2U4

Страница 1: ...MPS Ultra DC Power System INSTRUCTION MANUAL 855 340 032 Innovative Circuit Technology Ltd DC Power System Models ICT 2U4 ICT 2U5 ICT 2U6 ICT 2U8...

Страница 2: ...d current and size of battery fuse or circuit breaker Ensure battery polarity is correct before connecting Do not attempt to charge a frozen battery Handle batteries with care never short circuit batt...

Страница 3: ...nd Advanced Options 22 Password Reset Front panel 22 OPERATION Network GUI 23 Log In to the Unit 23 System 24 Power Modules 25 Battery Backup with optional Battery Management Module 26 Load Distributi...

Страница 4: ...KW models include battery state of charge estimated run time remaining and battery discharge testing Power Module Ratings Power Modules must be ordered separately Module 12V 50A ICT700 12 24V 25A ICT7...

Страница 5: ...larm relay connectors installed Plastic U shaped cover with four 6 32x1 4 screws for output bus bars in bag Four bolt washer nut sets for connections to the bus bars in bag Remote battery temperature...

Страница 6: ...W of output power ICT 2U8 positive or negative output Power Modules must be ordered separately Description Model No 12V 700W Power Module 13 8V 50A ICT700 12PM 24V 700W Power Module 27 6V 25A ICT700 2...

Страница 7: ...true N 1 redundant operation N 1 operation requires excess power module capacity to ensure that the load can be fully powered even if one power module should fail or be removed Carefully align each m...

Страница 8: ...ttery connection Only use the Equalize Charge setting for flooded lead acid batteries in a well ventilated location Do not use Equalize Charge on sealed batteries Always consult with battery manufactu...

Страница 9: ...e load limited only by the maximum output capability of the combined Power Modules One of up to twelve LDM Intelligent Output Channel Connector Ports Channel over current protection with LDM front cir...

Страница 10: ...this must be set according to the manufacturer s recommendation for your battery to enable charge voltage temperature compensation Battery temperature is assumed to be 25 C if no sensor is installed F...

Страница 11: ...ery to the BMMD Only use the Equalize Charge setting for flooded lead acid batteries in a well ventilated location Do not use Equalize Charge on sealed batteries Always consult with battery manufactur...

Страница 12: ...re 6 A Positive Voltage system will have the battery tied to the BMMD terminal with the battery tied to the main NEG output busbar Figure 7 Make Load Connections to LDM Up to three Load Distribution M...

Страница 13: ...ear figure 8 Figure 8 Install Parallel Control Cable Check that all connections to the power supply are correct and tight re install the plastic bus bar cover s using the screws provided Connect the A...

Страница 14: ...art up and operate at the factory default settings when AC power is connected generally requiring no other set up or adjustment for basic operation Use the front graphic display and four interface but...

Страница 15: ...using the up and down arrows the back button and the Enter button The output voltage and current limit settings apply to the combined output of all installed power modules The ICM treats the combined...

Страница 16: ...ld be adjusted to match your actual system and battery float voltage requirements as shown below Scroll to highlight the parameter to change System Voltage Max total Output Current Limit Output Enable...

Страница 17: ...status screen indicates the Battery Voltage Vdc the combined Battery Current Adc for charging Adc for discharging the approximate battery State of Charge SOC and a bar graph showing relative magnitude...

Страница 18: ...ystem can estimate the total battery SOC Also set the Battery Rate hrs used in the battery specification to determine the battery capacity Usually will be 20hr or 10hr rate Series connected batteries...

Страница 19: ...if messaging is configured via the Network GUI will indicate a Test Failure if the Stop Voltage is hit before the Max Time limit as the battery was not able to power the load for the desired duration...

Страница 20: ...ct location prior to snapping in place The LDM Status screen shows the output current for each of the four outputs plus indicates if a breaker is OPEN and if an output has been switched OFF LDM Settin...

Страница 21: ...the alarm inputs using the Network GUI interface The factory default setting has the alarm inputs disabled you must select a contact type for each input to enable it Alarm History Scroll through the...

Страница 22: ...gs and without interrupting DC power to the output terminals or Reset Comm Settings sets GUI password Communication settings and IP address to the factory defaults Note You will be prompted to enter t...

Страница 23: ...ess field of your browser as shown The default IP address of the unit is 192 168 0 180 but any MPS connected to a network with a DHCP server will be assigned a different IP address automatically To fi...

Страница 24: ...the internal alarm relay and the four remote alarm inputs Click on the SETTINGS CONTROL tab to configure all system related settings Click on the Save Settings button at the bottom of the page to stor...

Страница 25: ...x current requirement of the load and or battery Auto Restart Delay Auto Restart Delay Enter the delay time that the system output will remain disabled after the Auto Restart button is clicked The sys...

Страница 26: ...nt positive value for charging and negative value for discharging temperature if ICT TMP probe is installed Net Ah count approximate Ah discharged from the battery where 0Ah denotes full charge LVD st...

Страница 27: ...e total battery pack connected to the power system Connecting two batteries in parallel will double the total Ah capacity while connecting batteries in series will increase the voltage with no change...

Страница 28: ...disable this alarm default setting Alarm Reporting Activate Alarm Form C Contact Check this box default to have the back panel alarm contacts change state for an alarm condition Send E mail Check this...

Страница 29: ...lead acid batteries only A regular high voltage equalize charge will help prevent stratification of the electrolyte in your battery and can help extend its life Equalize Duration Enter the time durati...

Страница 30: ...more than 50 of the nominal battery capacity to avoid stressing the battery due to a deep discharge The Battery Discharge Test is only available if the system is configured for use with a lead acid t...

Страница 31: ...harge Tests Discharge test can only be initiated when the battery is fully charged If the system is unable to start a discharge test at the selected start time it will attempt again at the same time n...

Страница 32: ...le Control Module Output Control Output _ Click the On or Off button to remotely enable or disable that output channel All outputs are enabled as the factory default setting If power cycling is enable...

Страница 33: ...output channel if desired Output State after Power Loss Sets the state for an output channel after the LDM loses all input power then recovers Select one of the following Restore last State This will...

Страница 34: ...g DC bus voltage thresholds are not used and will be greyed out Load Shedding Auto Recovery Check this box to allow an output channel to be automatically reconnected when the bus voltage is above the...

Страница 35: ...NGS CONTROL tab to configure the input alarm settings Click on the Save Settings button at the bottom of the page to store your changes Alarm Input _ Alarm Name Enter a descriptive name for the select...

Страница 36: ...the bottom of the page to store your changes Power System Device Info Device Name Enter a device name for the system this will be used for all e mailed messages Model Hardware Model and hardware revis...

Страница 37: ...Output as the reset target will cause the main output to power cycle Data Logging Data Logging Select Enabled to keep a running record of all the key system parameters and alarms recorded once per mi...

Страница 38: ...with the panel HTTP Port Enter an HTTP port within the range of 1 to 65565 to be used for HTTP traffic between the panel and the browser The default HTTP port is 80 If a new HTTP port is selected the...

Страница 39: ...able SNMP Check this box to enable the SNMP agent SNMP Version Select the SNMP version v1 v2c v3 or All supported by the SNMP agent If All is selected all SNMP versions will be supported simultaneousl...

Страница 40: ...n protocol is selected enter the authentication password Privacy Protocol Select the SNMPv3 privacy protocol None or AES Privacy Password If a privacy protocol is selected enter the privacy password S...

Страница 41: ...d for this is available from your Network Administrator or Internet Service Provider ISP E mail SMTP Server Enter the name or the IP address of your SMTP server used for sending outgoing e mail e g sm...

Страница 42: ...one or more of these events occurs AC Input Power is lost Check this box to receive an e mail notification when the ac input drops below a functional level Power Module Failure occurs Check this box...

Страница 43: ...and change some of the basic settings View Only User can only view status cannot change any settings New Password Use these fields to change the password of the selected user New Password Enter the ne...

Страница 44: ...er Module Export and Import Settings The Manage Settings button will take you to the Export and Import Settings page where you may export all the system settings other than the Administrator password...

Страница 45: ...ng a Linksys WRT54G router others will be similar 1 Log into your router and go to the port forwarding screen In the example Linksys WRT54G router this is located in the Applications and Gaming tab Th...

Страница 46: ...assigned by the ISP With the example router this information is on the Status tab listed as IP Address NOTE When using a dynamic IP address the router s WAN IP address may change from time to time wit...

Страница 47: ...l phone number Cell address formats for some common North American mobile phone providers AT T cellnumber txt att net Verizon cellnumber vtext com Sprint cellnumber messaging sprintpcs com T Mobile ce...

Страница 48: ...he panel Verify that the Send E mail checkboxes are ticked for any alarm conditions for which you wish to receive e mail notifications Verify your e mail settings by going to the Communications Mainte...

Страница 49: ...ay Send Email2 Power Failure Loss of AC power to module Disabled Off Off Active Yes Module Operating Normal operation On Off On No Configuration Error Different voltage modules installed Off On Off Ac...

Страница 50: ...ition Output Relays ICM Required Alarm Relay Send Email3 Module Power Failure Loss of AC and DC bus connection Open No Yes No Alarms Normal Operation outputs enabled Closed No No Circuit Breaker Open...

Страница 51: ...r Factor 0 99 typ 120Vac input Efficiency typical 90 93 Output V Line Regulation 0 1 4 Actual Operating point may be lower due to battery charge requirement Power System 12V Module 24V Module 48V Modu...

Страница 52: ...e Temperature Range 40 to 70 C Humidity Operating 10 90 non condensing Storage 5 95 non condensing Cooling Load controlled fan on power modules Regulatory Compliance UL CSA 60950 1 UL CSA 62368 1 ICES...

Страница 53: ...e instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful i...

Страница 54: ...ipper regarding such damage Product that is returned as defective which is determined to operate within published specifications will be returned to the Purchaser freight collect ICT assigns to Purcha...

Отзывы: