Innovative Circuit Technology Ltd.
27
Configure Battery
Battery Type:
Configure the type of the battery used in the system (Lead-
Acid or Lithium-Ion).
WARNING
Always consult battery manufacturer's specifications when selecting battery
type. Incorrect battery type setting may damage your battery.
If Lithium-Ion type battery is selected, it must utilize an integrated battery
management system (BMS) to protect the battery cells from inappropriate
voltage or current levels.
Battery Capacity:
Enter the rated battery capacity
in Ah of the total battery
pack connected to the power system. Connecting two batteries in parallel
will double the total Ah capacity, while connecting batteries in series will
increase the voltage with no change to the Ah capacity.
Rate:
Select the discharge rate used by the battery manufacturer to
determine the battery capacity. Normally the 10 or 20hr rate is used. The
system will use this information to help determine the battery state of
charge, and remaining battery capacity when in use.
Battery Charge Current Limit
Charge Current Limit:
Enter the charge current limit to limit the maximum
battery charge current provided through the battery terminals while still
allowing the full rated current to be drawn from the main output. This