2-8
2
TAbLE 2-1 CONFIGURATION SETTINGS CONT’D
Setting
Choices Comments
9009 GPIB
0-30
9009 only - Sets the unit’s GPIB primary address.
Address
Addresses 0 and 21 should be avoided as they are
commonly used for the GPIB Controller’s address.
Default address is 4.
USB Prompt
On or Off 9009 only - Enables 9009 to return a prompt sequence
Enable
when ready for the next USB command. Prevents
overrunning the USB port.
USB Echo Enable On or Off 9009 only - Enables 9009 to return each character as
its received.
Modbus Baud Rate 1.2-115.2K Sets Modbus serial baud rate. Default is 9600.
Modbus Data Bits 7 or 8
Sets number of data bits in a character. Default is 8.
Modbus Stop Bits 1 or 2
Sets number of stop bits in a character. Default is 1.
Modbus Parity
None, even Sets Modbus serial parity. Default is none.
or odd
Modbus RS485
On or Off Off or 0 keeps the transmitter continuously on for
Mode
RS-232 and 4-wire RS-422/485 networks. On or 1
tristates the serial transmitter when not transmitting
for 2-wire RS-422/485 networks. Default is Off.
Slave Device
0-255
Sets the address the 9099 will use to address the
Address
slave Modbus device. This value can also be set by
the 9099’s Modbus ‘C’ command and by a Modbus
TCP/IP packet during Modbus TCP/IP operation.
Default is 1.
Substitute Slave
On or Off When off, the slave device address in the Modbus
Address Enable
TCP/IP packet is used to address the slave RTU
device. When on, the 9099 replaces the slave device
address in the Modbus TCP/IP packet with the Slave
Device Address. Modbus TCP/IP examples often use
a slave address of 0 which needs to be changed to the
actual Slave Device address.
Содержание 9099
Страница 20: ...1 16 1 Figure 1 1 9009 Outline Dimensions ...
Страница 24: ...1 20 1 Figure 1 3 9099 Certificate of Compliance ...
Страница 54: ...3 8 3 Figure 3 1 Status Reporting Structure Flash Configuration Reset ...
Страница 94: ...3 48 3 This page left intentionally blank ...
Страница 100: ...4 4 6 This page is left intentionally blank ...
Страница 161: ...A 49 A4 Refer to the ErrorLogger utility for the error value definitions Error Meaning 0 No error ...