5-4
5
TAbLE 5-2 TROUbLESHOOTING GUIDE
Possible
Symptom
Fault
Action or Check
Unit will not turn on Power supply not
Check for AC power at the
PWR LED off
plugged in or on
power adapter.
9009 missing jumper W14 missing. Install
per Section 2.7.
Power on board
Check 5V (TP4) testpoint.
3.3 volts missing
Check 3.3V (TP6) testpoint.
1.8 volts missing
Check 1.8V (TP5) testpoint.
Defective crystal
Check output of Y1 across
resistor R6.
LEDs stuck on
Internal fault
Check TP4 (5V), TP6 (3.3 V)
and TP5 (1.8V) for proper
voltage.
Defective unit
Return unit for repair.See 5.9.
Unit shows blinking
Self test fault
Refer to Self Test errors in
LEDs at power turn-on
Table 5-3.
No Network Activity ACT LED never on No network messages
received. Check network
router and gateways
for proper settings.
Wrong settings. PC and
9099's network setting must
be in the same IP B or C
Bad Ethernet cable. Try a
different cable.
LAN LED off
No network
Check cable, switch or PC for
proper operation.
IP address changed
Unit in DHCP and may have
been been given a new IP
address by the DHCP server.