N
Squelch attenuator
The transceiver has an RF attenuator related to the squelch
level setting. Approx. 10 dB attenuation is obtained at maxi-
mum setting.
The squelch attenuator allows you to set the minimum signal
level needed to open the squelch. The attenuator function can
be deactivated in FUNC set mode (SET).
±
Rotate
[SQL]
clockwise past the 13 o’clock position to ac-
tivate the squelch attenuator.
• Attenuation level can be adjusted up to 10 dB (approx.) between
13 o’clock and fully clockwise position.
Squelch is
open.
Squelch
attenuator
Squelch
threshold
Shallow
Deep
Noise squelch
NOTE:
The squelch attenuator functions even when the
monitor function is in use. We recommend setting the
[SQL]
control between the 10 and 13 o'clock positions
when using the monitor function.
D
Squelch attenuator setting
q
Enter “AT-ATT” in FUNC set mode (SET).
MENU
¶
SET
¶
FUNC
¶
AT-ATT
(p. 127)
(Push
[MENU
]
), (Rotate
[DIAL]
, then push
[
]
(MONI).)
[DIAL]
[MENU ]
[ ]
w
Rotate
[DIAL]
to turn the squelch attenuator function ON
or OFF.
• Select “OFF” to deactivate the squelch attenuator function.
e
Push
[MENU
]
to exit the set mode.