27
26
Button description
The machine stops after defrost.
Press the button“WASH”and discharge 400ml of the ingredient
and pour it back into the mix hopper.
Press the button “AUTO” and check the discharge amount of
ice cream after the machine completes generating ice cream
in the initial stage.
① Discharge continuously 5 cups of ice cream from the machine
and check the weight.
② Discharge 3 cups of ice cream from the machine after
10 minute pause from the comp operation.
③ Wait 4 minutes after the comp stops operating and discharge to test.
Examples
1) When set as 90g±35g at the rated voltage
5g 90g 125g
5
Average discharge amount distribution
ex) In case of discharge 4 minutes
after the comp stops (Freezer).
①
②
③
Adjust the 3-8-1 setting value lower
than the current voltage.
Set the 3-8-5 piston open time longer.
Set the 3-8-5 piston open time shorter.
ⓐ When the discharge
amount is less
ⓑ When the discharge
amount is more
5g 90g 125g
5
55g 90g 125g
55g 90g 125g
55g 90g 125g
2) In case of high/low voltage - ±10% of the rated voltage
CLASSIFICATION
ISI-273SH3S
ISI-273SH3S
ISI-273SHW3S
SETTING VOLTAGE
3PH 3W 220V / 60Hz
3PH 4W 400V / 60Hz
3PH 4W 380V / 60Hz
※ VOLTAGE CLASSIFIED TABLE