11
10
1. The water pressure must be in the range of 1~3kgf/㎠.
▶
Too much pressure will cause leak from the connected part.
2. If the product is installed where the temperature drops below 10℃, be sure to prepare a
freeze protection measure for the product.
▶
Otherwise, leak or product malfunction may occur.
3. The water supply must have a valve so that it can be closed in case of malfunction of the tap
on the top of the product.
※ The following must be checked when connecting the water supply!
Water
valve
※
The water supply valve may have different shapes depending
on the installation condition.
1. Insert the o-ring into the nut of the
wrinkled pipe and tighten the nut on
the water supply connector on the
lower back of the product with a tool.
2. Make sure that “A” is not damaged
in the process.
- To guarantee the optimal operation of the product, please consult our
technician on how to install the product.(Contact our authorized technician
in case of moving the product after the initial installation.)
- Avoid uneven surface or place with direct sunlight, too much dust,
or spattering water.
- If the product is to be used for an extended period of time,
reset the current time.
●
Connecting power
●
Follow this process!
●
Connecting the water supply
1. Use only a distribution box that supports specifications of 3-phase, 380V, and 60Hz.
2. Connect the earth leak breaker (higher than 30A) to the distribution box.
3. Ground the product for safety.
4. The distance between the right side and the back of the product must be longer
than 50cm, and that between the right side and the wall must be longer than 20cm.
5. Install the rubber feet correctly to prevent slippage.
Deeper than 30cm
Copper bar
or pipe electrode
Caution
If there is no grounding equipment at the installation area, be sure
to ground the product.
- Bury a copper bar or a pipe electrode deeper than 30cm
from the surface.
- Lack of proper grounding may cause electric shock due to leak.
Do not ground to the gas
pipe or water main.
There is danger
of accident.
Caution
50cm
20cm
50cm
For Your
Information
How to install
SOFT ICE CREA
M
PUSH
SPAST
EURIZ
E
STAND
-BY
STAND
-BY
SPAST
EURIZ
E
WASH
STOP
DEFR
OST
AUTO
SPAST
EURIZE
STAND
-BY
STAN
D-BY
SPAST
EURIZ
E
WASH
STOP
DEFR
OST
AUTO
SET
DEC.
L/R
INC.
SELEC
T
A
Water
-cooling
Air
-cooling
Содержание ISI-273SH3S
Страница 12: ...12 LEFT SIDE RIGHT SIDE Description of parts 900 ISI 273SH3S ISI 273SHW3S Drain slug Air cooling Water cooling...
Страница 13: ...13 BACK Description of parts ISI 273SH3S ISI 273SHW3S Pressure gauge Air cooling Water cooling...
Страница 54: ...54 MEMO...
Страница 55: ...55 MEMO...
Страница 56: ...3240273 00 Online Internet Service http www icetro com...